TECHNICAL DATA

TECHNICAL DATA

DIMENSION and INSTALLATION

DIMENSION and INSTALLATION

INTRODUCTION

Thanks for choosing a Wachendorff device.

Timer TI327401 can be set in 5 different modes: Timer-ON, Timer-OFF,
Pause-Work, Oscillator, PWM (time-proportioned output), all options
with independent setting of ON-OFF time.
3 digital inputs are available (NPN/PNP) for external commands like
Start, Stop, Reset; one input is also analogic in order to allow the
modification of working times by external potentiometer.
5 different time bases (hundredths, tenths, seconds, minutes, hours).
Counting can be incremental or decremental.

MEMORY CARD (optional)

MEMORY CARD (optional)

Parameters and setpoint values can be copied from one device to
another using the Memory card

There are two methods:

insert the memory card

.

On activation display 1 shows and display 2 shows

The device loads the new data and starts again

The memory card is equipped with an internal battery with a life of about 1.000
uses.

Insert the memory card and press the programming button.

When writing the parameters, the LED turns red and on completing the procedure
it changes to green. It is possible to repeat the procedure.

To

the memory card values, follow the procedure described in the first

method, setting display 2 to

so as not to load the parameters on controller.

Enter configuration and

.

Exit configuration. Changes are saved automatically.

This procedure restores the factory settings of the instrument.

With the device connected to the power supply

when the controller is off

With the controller disconnected from the power supply:

change at least one parameter

update

LOADING DEFAULT VALUES

. A

(Only if the values stored on Mmeory Card are correct).

By pressing the

key display 2 shows

Confirm using the

key .

.

ttention: pls. Perform first an update of the

memory card.

>

>

UPDATING MEMORY CARD.

PRESS

for 3 seconds

Display 1 shows

and 1st digit flashes,

display 2 shows

EFFECT

OPERATION

Or

Modify flashing digit,

press

to reach the following digit

Enter password

to confirm

Display shows first parameter

of configuration table

1

2
3

WIRING DIAGRAM

WIRING DIAGRAM

POTENTIOMETER 0 to 5/10 Kohm
Accuracy 1.000 points

P-01 Timer Function

Timer On
Timer Off
Pause/Work
Oscillator
PWM

FUNCTION CONFIGURATION

P-02 Power-off Memory

Disable
Only Timer
Timer / State

BACKUP MEMORY CONFIGURATION

P-03 Hardware Input 1

INPUT CONFIGURATION

LIST of PARAMETERS

LIST of PARAMETERS

Potentiometer:

1 use potentiometers 0 to 5/ 10kohm
2

connect cursor to pin I3; a wrong connection ma

damage the

potentiometer and lead to lock of th device.
3 accuracy on input is max 1000 points, therefore set the parameters "Upper
limit" and "Lower limit with a max difference of 1000 units.

4 To calibrate the scale of potentiometer enter t e configuration mode and
select:

To modify Set1 or Set2 by external potentiometer follow the steps below:

-
-

y

e

-

"

(Ex.: LoS1 to 50,0 and uPS1 to 150,0 to modify time value related to Set1 between
50 and 150 seconds with steps of one tenth). Greater differences would make
unstable the less significant digit.

-

h

Hin.3 as Pot
Fin.3 as Set1 or Set2
P.tAr as Enable
Exit configuration mode and place potentiometer at minimum level and press

key,

then place potentiometer at max level and press premere

key: the device

automatically exit the calibration procedure.
N.B.: A switch-off of the device would interrupt the calibration.

Timer operating modes

Activate output at elapsing of counting
Deactivate output at elapsing of counting
T1 and T2 start in sequence

Activate a percentage of output on a fixed time base

T1 and T2 start in sequence and cycling

Memory after switch-off

Disabled
Memory stores only value of Timer

START/STOP status

Memory stores value of Timer and

NPN
PNP
TTL

NPN
PNP
TTL

P-04 Hardware Input 2

Configuration Input 1

NPN
PNP
TTL

NPN
PNP
TTL

Configuration Input 2

Default

Default

Default

Default

SETPOINT CONFIGURATION

OUTPUT CONFIGURATION

DISPLAY CONFIGURATION

P-05 Hardware Input 3

P-06 Active State Input 1

P-07 Active State Input 2

P-08 Active State Input 3

PNP
TTL
Potent.

High Level
Low Level
Rising edge

High Level
Low Level
Rising edge

High Level
Low Level
Rising edge

Configuration input 3

Activate Input 1

Activate Input 2

Activate Input 3

PNP
TTL
Potentiometer

High level
Low level
Rising edge

High level
Low level
Rising edge

High level
Low level
Rising edge

P-09 Function Input 1

P-12 Function Key UP

P-10 Function Input 2

P-11 Function Input 3

P-16 Format Set 1

P-18 Display Set 1

P-17 Format Set 2

P-19 Display Set 2

P-13 Output Q1 Setup

P-14 Output Q2 Setup

P-15 Type of Timer

Disable
Start / Stop
Start / Stop-Reset
Reset-Start / Stop
Reset / Start / Stop

Second.Cent
Second.Decimal
Second
Minute.Second
Hour.Minute
Hour

Second.Cent
Second.Decimal
Second
Minute.Second
Hour.Minute
Hour

Disable
Start / Stop
Start / Stop-Reset
Reset-Start / Stop
Reset / Start / Stop
Reset
Wait
Hold

Disable
Out Timer 1 n.o.
Out Timer 1 n.c.
Out Timer 2 n.o.
Out Timer 2 n.c.
Start
Stop

Disable
Out Timer 1 n.o.
Out Timer 1 n.c.
Out Timer 2 n.o.
Out Timer 2 n.c.
Start
Stop

Incremental
Decremental

Disable
Visualized
Modifiable

Disable
Enable

P-24 Potent. tarature

P-20 Lower limit Set 1

P-21 Upper limit Set 1

P-22 Lower limit Set 2

P-23 Upper limit Set 2

Disable
Reset

Disable
Wait
Hold
Potent. To SET1
Potent. To SET2

Function of Input 1

Function of

key

Function Input 2

Function Input 3

Format of counting

Visualization of Set 1

Format of counting

Visualization of Set 2

Setting of output Q1

Setting of output Q2

Counting mode

Disabled
Start / Stop
Start / Stop-Reset
Reset-Start / Stop
Reset / Start / Stop

Seconds, Hundredths
Seconds, Tenths
Seconds
Minutes, Seconds
Hours, Minutes
Hours

Seconds, Hundredths
Seconds, Tenths
Seconds
Minutes, Seconds
Hours, Minutes
Hours

Disabled
Start / Stop
Start / Stop-Reset
Reset-Start / Stop
Reset / Start / Stop
Reset
Wait (stop the counting)
Hold

(hold value on display but counting goes on)

Disabled
Output Timer 1 N.O.

Timer 1 N.C.

Timer 2 N.O.

Timer 2 N.C.

Start
Stop

Output
Output
Output

Disabled
Output Timer 1 N.O.
Output Timer 1 N.C.
Output Timer 2 N.O.
Output Timer 2 N.C.
Start
Stop

Incremental
Decremental

Disabled
Visualized
Visualized and modifiable

Disabledd
Enabled

Calibration of potentiometer

Low limit Set 1

Upper limit Set 1

Low limit Set 2

Upper limit Set 2

Reset

Disabled

Wait

Modify SET1 by potentiometer
Modify SET2 by potentiometer

Disabled

(stop the counting)

Hold

(Hold value on display but counting goes on)

Default

Default

Default

Default

Default

Default

Default

Default

Default

Default

Default

Default

Default

Default

0.0

0.0

99.9

99.9

Default

PRESS

for 3 seconds

Display 1shows

and 1st digit flashes,

Display 2 shows

EFFECT

OPERATION

Or

Modify the flashing digit,

press

to reach the next digit

Enter password

to confirm

The device loads default values

(factory settings)

Switch-off and restart

the device

1

2

3

Scroll the parameters

4

Or

Increade or decrease value on display

by pressing

and one of the arrow keys

at same time

Enter new data

which will be stored

releasing the keys

5

+

Or

End of configuration,

the device exits programming mode.

6

MODIFY PARAMETERS

LOADING DEFAULT SETTINGS

LOADING DEFAULT SETTINGS

PRESS

Display SETPOINT 1 / 2

EFFECT

OR

Modify selected SETPOINT

Select the chosen digit

1

2

2a

Modify the flashing digit of the selected setpoint

3a

O

MODIFY SETPOINT

MODIFY SETPOINT

Proximity
sensor PNP
3 wires

Proximity
sensor PNP
2 wires

+

-

OUT

OUT

PNP

NPN

PNP

NPN

Read carefully the safety guidelines and programming instructions
contained in this manual before using/connecting the device.

Disconnect power supply before proceeding to hardware settings or
electrical wirings.

Only qualified personnel should be allowed to use the device and/or
service it and in accordance to technical data and environmental
conditions listed in this manual.

Do not dispose electric tools together with household waste materials in
observance of European Directive 2002/96/CE

Operating

temperature

Sealing

Material

Digital

Inputs

Outputs

OUT 24V

Back-UP

Programming

Software

Power Supply

Operating temperature 0-40°C, humidity 35..95uR%

PC ABS UL94V0 self-extinguishing

3PNP/NPN configurable as analogue for potentiometers.
(max 28 Vdc in PNP mode)

2 relays 5A resistive charge
30mA(24Vac),40mA(24 Vdc),60mA (110...230Vac)

Rechargeable battery, approx. 7days autonomy

Labsoftview 2.6 or later

24...230Vac/Vdc +/-15% 50/60Hz / 2W

Front panel IP65 (with optional gasket) ,
Box IP30, Terminal blocks IP20

.

Wachendorff Prozesstechnik GmbH & Co. KG

www.wp-direkt.de

e-mail: [email protected]

Version 2.0

MANUAL

TIMER TI327401

MANUAL

TIMER TI327401

1

2

3

Front panel

cut out

28.5 x 70.5 mm

2 to

mm

suggested thickness

8

77 mm

35

mm

53 mm

7

CN1

1

6

PIXSYS

Memory card (optional)
with battery (SFUR0KIT)

Gasket

5A230V

Resistive

1/2HP

Q1

5A230V

Resistive

1/2HP

Q1

5A230V

Resistive

1/2HP

Q2

5A230V

Resistive

1/2HP

Q2

Speicher

Speicher