H5CR

  Multifunction Digital Timer

1/16 DIN Timer with Easy-to-use 
Functions

Nine output modes accommodate a wide variety
of applications.

All parameters set by scroll-through menus
accessed from the front panel.

Field-selectable time ranges from 0.001 second to
9999 hours.

High visibility LCD display with built-in backlight.

Precision control possible to 0.001 second.

Four levels of key protection provided.

Selectable elapsed time (UP) and remaining time
(DOWN) display.

Model H5CR-S only 64 mm deep.

Conforms to EMC standards.

Six-language instruction manual provided.

Ordering Information

Note:

Add the supply voltage to the part number when ordering.

Model Legend

Note:

Models with a finger safe terminal cover can be ordered by adding “-500” to the end of the model number. (Except for H5CR-L

#

)

e.g., H5CR-B-500 (100 to 240 VDC, 50/60 Hz)
The finger safe terminal cover provides finger protection conforming to VDE0106/P100.

RC+

Functions

9 field selectable

Contact type

SPDT relay

Solid-state open collector

Unit Depth

Basic (78 mm)

Standard 

(100 mm)

Short body 

(64 mm)

Basic (78 mm)

Standard 

(100 mm)

Short body 

(64 mm)

Display

Backlit

---

H5CR-B

H5CR-S

---

H5CR-BS

H5CR-SS

Not backlit

H5CR-L

---

---

H5CR-LS

---

---

Supply 
voltages

AC

24/100 to 240 V, 
50/60 Hz

24/100 to 240 V, 
50/60 Hz

---

24/100 to 240 V, 
50/60 Hz

24/100 to 240 V, 
50/60 Hz

---

DC

12 to 24 V

---

12 to 24 V

12 to 24 V

---

12 to 24 V

H5CR -           

2. Output type classifier
   Blank:   Relay output
   S:   

Solid-state output

1. Type  classifier
   L:   Basic
   B:   Standard
   S:   Short body

Summary of Contents for H5CR series

Page 1: ...number when ordering Model Legend Note Models with a finger safe terminal cover can be ordered by adding 500 to the end of the model number Except for H5CR L e g H5CR B 500 100 to 240 VDC 50 60 Hz The finger safe terminal cover provides finger protection conforming to VDE0106 P100 RC Functions 9 field selectable Contact type SPDT relay Solid state open collector Unit Depth Basic 78 mm Standard 100...

Page 2: ...splay modes Elapsed time UP remaining time DOWN Output modes A A 1 A 2 A 3 b b 1 d E F Reset system Power reset except A 3 b 1 and F modes External manual automatic resets internal according to A 1 b b 1 d and E mode operation Input signals Start reset inputs Start reset gate key protect inputs Input method No voltage input Via opening and closing of contact Control outputs SPDT contact output and...

Page 3: ... current carrying terminal and exposed non current carrying metal parts and between non continuous contacts Dielectric strength 2 000 VAC 50 60 Hz for 1 min between current carrying terminal and exposed non current carrying metal parts for 100 to 240 VAC type 1 000 VAC for 24VAC 12 to 24 VDC transistor output type Surge voltage 3 kV between power terminals for 100 to 240 VAC type 1 kV for 24 VAC 1...

Page 4: ...tor not included in the H5CR L 6 Control output indicator 7 Present value character height 8 mm Non significant zeroes suppressed 8 Set value character height 4 mm Indicates value in set function mode 9 Mode indicator 10 Timing indicator Display 11 Increment keys 1 to 4 Used to change the corresponding digit of the set value Used to change data in the set mode 12 Display key Switches to the presen...

Page 5: ...ected indicator lit while key protect input is ON Effective when power supply is turned off Effective when protect terminals are shorted Outputs Control output OUT Outputs made according to designated output mode when corresponding preset is reached Key switch circuits Input circuits Re set control signal key protect gate AC DC input LCD drive clock generator RAM Power circuits System clock genera...

Page 6: ...nput signal time Output time Output mode UP DOWN mode Setting mode Press the DISPLAY key Press the MODE key Press the MODE key Press the MODE key Press the MODE key Press the MODE key Press the MODE key Press the MODE key Note 1 Set values are changed using the increment keys 1 to 4 2 The large arrows indicate the parameter displayed first when the mode is changed with the MODE or DISPLAY key 3 Th...

Page 7: ...displayed when the out put mode is d E or F Input signal time Changes the duration of the control and reset input signals Key protect level Locks certain keys to prevent acci dental operation The key protec tion level kP 1 to kP 4 determines which keys are locked when the key protection input is ON The locked keys are crossed out in the diagram on the right 0 1 2 8 9 Sequence when changing a digit...

Page 8: ... eration Setting Mode Changing Settings in the Set Mode 1 Press the MODE key to switch from run mode to set mode The Timer will continue operation if switched from run mode to set mode during operation The MODE key will be locked if the key protection function is enabled Settings changed in the set mode are not effective until run mode is entered As the operating conditions will change in this cas...

Page 9: ...ng diagram UP DOWN 0 0 Set value Timing starts when the start signal goes ON and is reset when the start signal goes OFF While the start signal is ON the timer starts when the power comes ON or when the reset input goes OFF The control output is controlled using a sustained or one shot time period Output is instantaneous when setting is 0 Basic Operation Power Start signal input Timing Output Powe...

Page 10: ... the value to at least 100 ms contact output type Start signal input is disabled during timing Basic Operation Power Start signal input Output Timing Timing Timing Timing Power Start signal Gate Reset Control output Set value Timing diagram UP DOWN 0 0 Set value Sustained Output Timing starts when the start signal goes ON The status of the control output is reversed when time is up OFF at start Wh...

Page 11: ...en the time is up Output functions only during start signal input when setting is 0 Start signal input is enabled during timing Basic Operation Power Start signal input Output Timing Power Start signal Gate Reset Control output Set value Timing diagram UP DOWN 0 0 Set value Timing starts when the start signal comes ON The control output is reset when time is up While the start signal is ON the tim...

Page 12: ...ns Note All units are in millimeters unless otherwise indicated 48 48 84 0 63 7 6 0 7 14 3 44 8 x 44 8 48 48 6 64 44 8 x 44 8 H5CR L Surface Flush Mounting H5CR B Flush Mounting H5CR S Flush Mounting 48 48 100 6 44 8 x 44 8 ...

Page 13: ...ting adapter Panel Y92F 30 Flush mounting adapter Panel Note 1 The mounting panel thickness should be 1 to 4 mm 2 It is possible to mount timers side by side but only horizontally H5CR L P2CF 08 58 48 6 64 60 min 60 min 45 0 6 0 45 0 6 0 1 0 A 48n 2 5 n 1 x 4 Panel Y92F 30 Flush mounting adapter P3G 08 Rear surface connection socket 44 8 x 44 8 With Y92A 48F1 attached 44 8 x 44 8 1 0 A 51n 5 5 Wit...

Page 14: ...Surface Mounting Holes 40 0 2 Two 4 5 dia or two M4 50 max 40 0 2 70 max Eight M3 5 x 7 5 sems Two 4 5 dia holes 7 8 4 35 4 21 5 max 20 3 19 3 1 3 5 4 5 45 27 dia 45 4 9 17 Back Connecting Socket P3G 08 Terminal Arrangement Internal Connections Bottom View Finger Safe Terminal Cover Conforming to VDE0106 P100 Y92A 48G Attachment for P3G 08 Socket Y92A 48T Attachment for H5CR B S Hard Cover Y92A 48...

Page 15: ...3 4 5 Input use 0 V Reset input Gate input Key protect input OUT 100 to 240 VAC 24 VAC Unused Unused Start signal input Transistor output 12 to 24 VDC 11 12 6 7 8 9 10 1 2 3 4 5 Input use 0 V Reset input Gate input Key protect input OUT Unused Unused Start signal input The inputs of the H5CR are no voltage short circuit or open inputs No voltage Input Signal Levels No contact input Contact input 1...

Page 16: ...e is changed accidentally during operation the timer might be activated Therefore turn the key protection input ON unless the set value is being changed To avoid changing the output when changing the set value it is recommended to begin changing the set value by entering a large number in the higher digit Operation with a Set Value of 0 Operation with a set value of 0 will vary depending on the ou...

Reviews: