4.3 Electrical installation OPUS A3
Below you find the pin out diagram of the OPUS A3. The connectors are drawn as
seen from the back side of the unit.
Please be aware that the existing pins and connectors depend on the hardware
option you ordered.
Please note that the OPUS A3 only represents one part of the entire CAN network.
Set-up and dimensioning of the network must be executed by specialized personnel,
and the information in this regard cannot be a component of this operating manual.
Ethernet
Round Connector,
4 pins, M12,
acc. To IEC 61076-2-101
1
TD+
2
RD+
3
TD-
4
RD-
Video
Round Connector, 5
pins, M12
1
2
Mirror
3
4
Camera -
5
VidSig GND
Video connector pinout
Ethernet Connector,
M12, female, 4 pins,
d-coded
Video- Connector,
M12, female, 5 pins,
b-coded
Main Connector
Ethernet connector pinout