82
DMS9648O - User manual
Description
Reset value
9012
Data logger: flag end memory. 0 indicates that
memory is still available. 1 indicates memory is
saturated and device restarted to store data from
address 9033/9034 (H)
RO EEPROM
9033 First analogue input value stored (L)
RO EEPROM
9034 First analogue input value stored (H)
RO EEPROM
9035 Second analogue input value stored (L)
RO EEPROM
9036 Second analogue input value stored (H)
RO EEPROM
...
...
RO EEPROM
10031 Last analogue input value stored (L)
RO EEPROM
10032 Last analogue input value stored (H)
RO EEPROM
* Parameters modified using serial address 4001 to 4300, will be stored on eeprom only after 10s
since last writing of one parameter.
11
Error messages
The instrument signals failures/anomalies by means of messages on the display.
The following are the possible messages:
Probe error
Detected a fault in the load cell or on the Melt sensor.
The control on sensor is executed at each device
starting.
Read Eeprom failure Error during Eeprom memory reading
Write Eeprom fail
Error during Eeprom memory writing
Wrong tarature data Error on device calibration data
Wrong parameters
Error on device configuration parameters
Wrong status data
Error on device status data
Param. out of range Detected a parameter value out of range.
Missing calibration
Error on device calibration data
In all of these situations, the instrument might not be able to operate correctly.
Switch it off and back on. If the problem persists, contact assistance.