SAFETY RULES
To reduce the risk of electric shock, ensure electricity has been turned off at
the circuit breaker before beginning.
All wiring must be in accordance with the National Electrical Code “ANSI/
NFPA 70” and local electrical codes. Electrical installation should be
performed by a licensed electrician.
The fan must be mounted with a minimum of 7 ft. (2.1m)
clearance from the trailing edge of the fan blades to the floor
and a minimum of 1.5 ft (0.5m) from the edge of the fan blades to the
surrounding walls.
Never place objects in the path of the fan blades.
To avoid personal injury or damage to the fan and
other items, please be cautious when working around
or cleaning the fan.
To avoid electrical shock or damage to the motor or finish, do not use water
or chemicals when cleaning the fan or fan blades. A dry cloth or lightly
dampened cloth will be suitable for most cleaning.
After making electrical connections, spliced conductors should be turned
upward and pushed carefully up into the outletbox. The wires should be
spread apart with the grounded conductor and the equipment-grounding
conductor on one side of the outletbox, and the ungrounded conductor on
the other side of the outletbox.
All set screws must be checked and re-tightened where necessary before
installation.
For operation, maintenance, and troubleshooting information, visit http://waclighting.com/fan-support/