INSTRUCTIONS 

 

 

Class II Electronic Transformer 
Model EN-1260-RB2 

         

 

CAUTION – TO REDUCE RISK OF FIRE AND ELECTRICAL SHOCK 

  Always turn off power at main switch prior to installation. 

  Intended for installation by a qualified electrician.  

  System is intended for installation in accordance with National Electric Code, and local 

regulations. Consult with local inspector to assure compliance. 

 

 

 

MAX LOAD 

60W 

MIN LOAD 

20W 

INPUT VOLTAGE 

120V 

INPUT CURRENT 

0.53A 

OUTPUT VOLTAGE 

11.6V 

CASE TEMP 

90ºC (194

F) 

AMBIENT TEMP 

-20ºC TO 50ºC (-4

F TO 122

F)  

 
FEATURES: 

  Electronic short circuit protection with auto-reset.  

  Overload protection with auto-reset. 

  Automatic thermal regulation. 

 

Soft start delay to preserve bulb life, for use with tungsten filament lamps. 

 

INSTALLATION 

1.  Use a minimum of #18 AWG for the output wire. 
2.  Transformers must be installed away from heat sources and accessible for service. 
3.  Note: Enclosed transformer is UL listed. The transformer box has a separate line volt, 

and low volt wiring compartments. Trade size knock out are provided on both 
compartments. Connect building wires to like color transformer wires with wire nuts. 
Building ground wire may be green or un-insulated, and attaches to green wire from 
transformer box.  

4. 

Connect out put wires from transformer to fixture wires with wire nuts. Where multiple 
fixtures are involved several fixtures wires can be joined by use of the same wire nut. 
Wires to fixture