![background image](http://html1.mh-extra.com/html/wac-lighting/dweled-689-series/dweled-689-series_installation-instructions_3118919002.webp)
dweLED.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia
Springs,
GA
30122
Western Distribution Center
1750 Archibald Ave
Ontario, CA 91761
dweLED
retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
Feb 2019
2
C
INSTALLATION INSTRUCTIONS
689-Outdoor Wall Sconce
WS-W68913/WS-W68917
Fig.1
PREPARATION
1.
Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.
2.
Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for
installation.
MOUNTING THE FIXTURE (Fig. 1)
3.
Remove the mounting screw (B) and rubber gasket (C) from the fixture.
4.
Secure the mounting back plate to the junction box using the screws provided with the junction box.
NOTE:
The side of the mounting plate marked “GND” must face out.
5.
Remove the set sc
rew
(D) from the fixture.
6.
Insert the seed
ed
glass into the fixture,
attach
it
to
bottom border using set screw (D).
CONNECTING THE WIRES (Fig. 2)
7.
Connect the driver’s input wires to junction box wires as shown (Fig. 2). Make sure that all wire connectors (A) are secure. If
your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s
ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the
junction box.
NOTE:
This fixture features electronic low voltage (ELV or TRAIC) or 0-10V dimming capabilities. See notes below for specific
dimming
wiring information.
COMPLETING THE INSTALLATION
9.
Secure the fixture to the mounting back plate using the mounting screw (B) and the rubber gasket (C).
10. To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to
outline the outside of fixture back plate where it meets the wall. Leave a space at the bottom to allow moisture to escape (Fig.3).
NOTE: DIMMING WIRING INFORMATION (Fig. 4)
12. To utilize ELV or TRAIC dimming: use black (hot), white (neutral) and bare copper ground wires (ground).
13. To utilize 0-10V dimming: use purple (dim+), gray (dim-), black (hot), white (neutral) and bare copper ground wires (ground)
Fig.
2
Wiring
Fig. 4
Fixture-
Gray