INSTALLATION INSTRUCTION

S

486 - LED Outdoor

WS-W48612,  WS-W48616,  WS-W48620

FIG.1

Junction Box Screw

Mounting Screw

Rubber Gasket

Junction Box

Ground Wire

Mounting Back Plate

Wire Connector

Back Plate Dimensions

White Wire

Black Wire

B1

C1

D1

A1

Fixture Wires

Black or 

Smooth

Fixture Wires

White or 

Ribbed

Fixture Wires

Bare wire

(Ground)

House Wires

Black

(Hot)

House Wires

White 

(Neutral)

House Wires

Green or Bare Copper

(Ground)

Fig. 2 Wiring

Junction Box

Caulking

Fig.3  Sealing

PREPARATION  

1.

Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.

2.

Carefully unpack your new fixture and lay out all the parts on a clear area.  Be careful not to lose any small parts necessary for installation.

MOUNTING THE FIXTURE 

(Fig. 1)

3.

Remove the mounting screw (C1) and the rubber gasket (D1) from the mounting back plate.

4.

Secure the mounting back plate to the junction box using junction box screws (B1).

NOTE: 

The side of the mounting back plate marked “GND” must face out.

CONNECTING THE WIRES 

(Fig. 2)

5.

 

Connect the fixture’s wires to junction box wires as shown

 (Fig. 2). Make 

sure that all wire connectors (A1) are secure.  If your outlet box 

has a green or bare copper ground wire, connect the fixture’s ground wire to it.  Otherwise, connect the fixture’s ground wire directly to the 

back plate using the green screw provided.  After wires are connected, tuck them carefully inside the junction box.

COMPLETING THE INSTALLATION 

(Fig. 1)

6.

Secure the fixture to the mounting back plate using the mounting screw (C1) and the rubber gasket (D1).

7.

To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline 

the outside of fixture back plate where it meets the wall.  Leave a space at the bottom to allow moisture to escape

 (Fig. 3).

WS-W48612   5 3/4"

WS-W48616   7 5/8"

WS-W48620   9 1/4"

1 3/8"

1 3/4"

WS-W48612   4 1/8"

WS-W48616   5 1/8"

WS-W48620   5 5/8"