S-SERIES PRIVATE USE SERVICE MANUAL
INSTRUCTIONS
SEPTEMBER 2020
32DSSP05.D
2 - 14
e.
Load Passenger
Carefully place wheelchair in center of platform, facing outward (away from vehicle),
and lock wheelchair brakes.
2.
LOWER PLATFORM
CAUTION
Do not open pump release valve more than ¼ turn. Opening valve further may
cause it to disengage from pump body, which will disable manual pump.
a.
Refer to
Figure 2-13
. Turn valve 1/4 turn counter-clockwise to begin lowering plat-
form.
b.
Hold valve open until platform settles at ground level. Refer to
Figure 2-14
. Turn
valve clockwise to close; do not over-tighten valve.
c.
The outer barrier will open automatically as the platform settles to the ground.
d.
Release wheelchair brakes and carefully exit platform.
3.
STOW PLATFORM
a.
Refer to
Figure 2-14
. Verify that pump release valve is closed; do not over-tighten
valve.
b.
Refer to
Figure 2-15
. Insert pump handle into pump handle socket. Operate pump
to begin folding platform.
c.
Operate pump until platform is completely folded inside vehicle and Stow lock has
engaged.
d.
Stow pump handle. Close vehicle doors.
FIGURE 2-15: RAISE PLATFORM