1.
General safety regulations
Read, before you perform any action in connection with
the tester, this user manual carefully.
Mors Smitt B.V. is not liable for injuries, (financial) da-
mage and/or excessive wear resulting from incorrectly
performed maintenance, incorrect use of or modificati-
ons to the instrument.
It is not allowed to remove, to skirt or to tide over (by
handy constructions) the enclosure or safeties of the
tester during normal use. Method of measurement and
range are indicated on the back side of the instrument.
It’s forbidden to place and/or to use the instrument in a
room where is a risk of explosion.
If the tester is used by a third party, you being the owner
are responsible, unless otherwise specified.
Repair can only be done by Mors Smitt B.V.
Provide a clean and safe workplace which has sufficient
lightning.
2.
Introduction
2.1
General
The working conditions Act (ARBO-law) is intended to ensure the safety
of the employee in the workplace. In EN 50110 and NEN 3140, the
safety requirements and tests relating to the electrical installation and
electrical appliances/tools further developed.
2.1.1
Intended use
The RCT-C tester is intended to be used for checking of the safety of
electrical installations.
The RCT-S is intended for execution of all tests concerning different
protective switches with differential current protection. If the instru-
ment is used in manner not specified in this user manual, the protec-
tion provided by the instrument may be impaired and the supplier is
excluded from any responsibility.
Structure
The RCT-S is an electronic controlled instrument intended for the
execution of all tests concerning different protective switches with dif-
ferential current protection (with or without switch-off delay)
RCD types which can be tested by RCT-S:
1.
The sensitivity according to the form of the fault current
- type AC
2.
The disconnection delay
- without delay (standard type)
- with delay (selective type)
3.
The rated values of the fault currents
-10 mA; 30 mA; 100 mA; 300 mA; 500 mA ; 650mA
Connection
The instrument is powered by four AA batteries. The tester is provided
with a on/off switch and can after powering up the instrument, be used
at once.
Measuring
The following measurements can be executed by the instrument:
1. The tripping time (t) at the current of IΔN
2. The trip out current (IΔ)
3. The mains voltage between the phase and the protective earth
terminals
Summary of Contents for Mors Smitt NIEAF SMITT RCT-C
Page 1: ...Nieaf Smitt is a brand name of Mors Smitt RCT C Aardlekschakelaartester Handleiding ...
Page 12: ...12 www nieaf smitt com Nieaf Smitt is a brand name of Mors Smitt ...
Page 13: ...Nieaf Smitt is a brand name of Mors Smitt RCT C tester RCD tester Manual ...
Page 23: ...23 www nieaf smitt com Nieaf Smitt is a brand name of Mors Smitt ...