TP-0357
Revised 06-19
(16579)
Page 2
Copyright WABCO, Inc. 2019
Printed in the USA
Figure 1
Installation
Guidelines
NOTE:
If you are installing the inversion relay valve on an existing
installation, you must first remove the old valve. Refer to the valve
replacement procedure in this bulletin for instructions.
1.
Mount the valve.
앫
Refer to the vehicle manufacturer’s specifications for
specific mounting requirements.
앫
Select a flat mounting surface. The mounting surface must
be within 0.010-inch (0.25 mm) of flat.
앫
For best timing results, mount the valve near the spring
brakes it will serve.
앫
Mount the valve with the exhaust port facing down within
30
°
of vertical.
앫
Use 8 mm mounting hardware to attach the valve to the
mounting surface. Tighten to 15
±
2 lb-ft (20
±
3 N
폷
m).
Figure 2.
@
Figure 2
2.
Connect the air lines as indicated in Table A. Valve ports are
identified in Figure 3.
앫
Make sure all unused supply and delivery ports are
plugged.
앫
Look at the air line installation to make sure all air lines are
correctly installed and that all connections are secure.
Figure 1
4003018b
ACC
PURGE
TANK
WET
TANK
PRIMARY
RESERVOIR
SECONDARY
RESERVOIR
AIR
FROM
INLET
FILTER
SUPPLY LINE
PARKING BRAKE
CONTROL LINE
Figure 2
EXHAUST
4003006a
PRODUCT
IDENTIFICATION