![WABCO 973 002 Test Instruction Download Page 8](http://html1.mh-extra.com/html/wabco/973-002/973-002_test-instruction_866086008.webp)
8/9
© 2006 American Standard All rights reserved 973 002 981 3/05.2006
4
Test side valve
Fig. 4 Test diagram "Side Valve"
Orifice diameter 2.5
8 bar
Manometer 11
Manometers 12/21
Shut-off cock 11
42
1 dcm³
Manometer 41
Shut-off cock 41
Fine control valve 41
8 bar
Shut-off cock 22
Shut-off cock 43
11
41
22
12
Shut-off cock 21
Manometer 22
21
43
Manometer 43
8 bar
Fine control valve 22
Test step
Manometer (M)
Comment
Default value
Test value
M 11
bar
M 41
bar
M 22
bar
M 43
bar
M 12 /
M 21
bar
Shut-off cocks 12, 21 and 22:
Open the pass.
Shut-off cock 12/21: Shut the
pass.
0
0
0
0
0
Fine control valve 41:
Increase pressure.
0
2,7
0
0
0
Fine control valve 22:
Increase pressure.
0
2,7
2,5
0
0
Fine control valves 11 and 43:
Increase pressure.
5,5
2,2
2,5
5,5
-
Pressure flows off via nozzle at
connection 21:
Fine control valve 41:
Increase the pressure until the
pressure drops by 3.5 bar at
M 12/21 (test bench: M 3).
Wait for this value at M 12/21,
then test M 41 (test bench:
M 2).
-
-
2,7
4,5...5,3
2,5
2,5
5,5
5,5
M 12/21
- 3.5 bar in
compari-
son to the
value in
the line
before.
-
Precision control valve 11, 22,
41 and 43: Reduce the pres-
sure.
0
0
0
0
0