![WABCO 1200E Maintenance Manual Download Page 7](http://html2.mh-extra.com/html/wabco/1200e/1200e_maintenance-manual_3106167007.webp)
1
Introduction
3
Meritor WABCO
Maintenance Manual 34 (Revised 03-16)
Air Dryer Cycle
A single cartridge air dryer cycle is illustrated in Table A.
Table A
The governor turns the compressor on when supply tank pressure
drops below cut-in pressure, between 100 psi and 110 psi
(689-758 kPa) depending on governor settings.
Compressed air passes into the air dryer at the inlet port:
앫
Moisture-laden air and contaminants pass through the
desiccant.
앫
Moisture is retained by desiccant; moisture also collects in the
base of the dryer.
앫
Contaminants are removed as air passes through the desiccant
bed.
The governor turns the compressor off when system reaches
cut-out pressure, between 120 psi and 130 psi (827-896 kPa)
depending on governor settings.
1002142a
CONTROL
“WET” AIR
“DRY” AIR
CONTROL/DRY
LINES
ENGINE TURBO
BOOST PRESSURE
1002143
a
1002145a
CONTROL
“WET” AIR
“DRY” AIR
CONTROL/DRY
LINES
ENGINE TURBO
BOOST PRESSURE
Summary of Contents for 1200E