W. Tombling HC1500 Instruction Manual Download Page 1

Ceramic Infrared Heaters

The  following  information  should  be  considered  when  installing 
ceramic infrared heaters.

Installation  must  be  carried  out  by  a  competent  person  in 

accordance with the current edition of the IEE Wiring Regulations 

(BS  7671:  Requirements  for  Electrical  Installations)  and  any 

applicable statutory regulations.

The heater should be preceded by a double pole isolating switch 

preferably with an indicator light.

The heaters should always be installed using the mounting 

brackets  provided  to  ensure  adequate  clearance  from  the 

wall.

Do not touch the heater while it is operating, the surfaces are 

hot!

Do not cover the heater, point it a flammable objects, or place 

items closer than the stated safety distance as this result in a 

risk of fire

Heaters  should  not  be  installed  in  areas  where  hazardous 

vapours may be present as defined in BS5345

It is recommended the heaters are operated with the element 

guard  in  place.  The  safety  guards  are  only  intended  to 

prevent large objects from directly hitting the ceramic emitters.

Some  applications  will  necessitate  additional  precautionary 

measures.

A build up of moisture in the emitter can cause earth leakage 

currents to flow, causing RCD’s to trip. Operating the heater 

for  a  few  minutes  with  the  RCD  removed  will  expel  the 

moisture and cure the problem. Where heaters with ceramic 

emitter  are  installed  in  damp  or  wet  areas  they  should  be 

used regularly to stop moisture building up in the emitters.

Where RCD protection is used the heaters should be installed 

over several circuits, each with its own protective device.

The heater should only be installed in an indoor or weather 

protected environment.