Features 

          

 

 

 

 

 

• High impact molded polypropylene enclosure

• Heavy duty dynamic switch mode power supply

• Built-in highly efficient class D amplifier

• 10”, 12” or 15” Mid-Low frequency transducers

• 1” Compression high frequency driver

• 80˚ x 60˚ Coverage pattern

• Smooth response with high power

• 5 Integral suspension points

• Complete mounting solutions

Specifications:

Freq. Range(-10dB):
Freq. Response(-3dB):
Rec. Hi pass Frequency:
Max Calculated SPL:
Horizontal Coverage:
Vertical Coverage:
Amplifier Power LF:
Amplifier Power HF:
LF Transducer:
HF Transducer:
Crossover Frequency:
Loop/Mix Out:
AC Input:
Dimensions (H×W×D):
Net Weight:
Shipping Weight:

DSR-10A

60Hz~19kHz
70Hz~19kHz

40Hz

123dB

80˚
60˚

300W

50W

10”/50mm

1”/25mm

2.5kHz

XLR/M,Balanced

220-240V ~ 50/60Hz

557 x 332 x 313mm

14.5Kgs
16.5Kgs

DSR-12A

56Hz~19kHz
65Hz~19kHz

40Hz

125dB

80˚
60˚

400W

50W

12”/50mm

1”/25mm

2.2kHz

XLR/M,Balanced

220-240V ~ 50/60Hz

615 x 416 x 356mm

17Kgs

19.5Kgs

DSR-15A

45Hz~19kHz
55Hz~19kHz

40Hz

127dB

80˚
60˚

450W

50W

15”/65mm

1”/25mm

2.2kHz

XLR/M,Balanced

220-240V ~ 50/60Hz

740 x 475 x 400mm

22.5Kgs
25.5Kgs

Summary of Contents for DSR 10A

Page 1: ...ENGLISH USER MANUAL Order Code SPEA34 DSR 10A Order Code SPEA35 DSR 12A Order Code SPEA36 DSR 15A...

Page 2: ...AUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult...

Page 3: ...y handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available voltage is between 220v 240v Make sure that the power cable is never crimped or dam...

Page 4: ...L Horizontal Coverage Vertical Coverage Amplifier Power LF Amplifier Power HF LF Transducer HF Transducer Crossover Frequency Loop Mix Out AC Input Dimensions H W D Net Weight Shipping Weight DSR 10A...

Page 5: ...Specifications DSR 10A DSR 12A Dimensions Dimensions Dimensions DSR 15A Freq chart Freq chart Freq chart Block diagram Block diagram Block diagram 4...

Page 6: ...elescopic tubes you must always block a safety area around the stand This safety area must have a diameter of 1 5 times the maximum height Lifted telescopic tubes always have to be secured with a seco...

Page 7: ...ter every four years in the course of an acceptance test The operator has to make sure that the safety installation data is approved by a skilled person once a year Procedure The speaker should be ins...

Page 8: ...he threaded holes on the speaker The eye bolts must be tightened until the stop position hand tight with out any tools Insert the quick links of the safety ropes in the eye bolts of the speaker system...

Page 9: ...l must be chosen to suit the wall material Always ask a specialist for the correct plug screw combination indicating the maximum load and building material Suspended Installation DANGER TO LIFE The sp...

Page 10: ...9...

Page 11: ...10...

Page 12: ......

Reviews: