8
Symptom
Cause
Recommended action
The machine will not
start
The machine is not plugged-in Plug the machine in
The fuse has blown
Replace the fuse Unplug other appliances
Faulty extension cable
Try without the extension cable
Fluctuating pressure
The pump is drawing in air
Check that hoses and connections are airtight.
Valves dirty, worn or sticking Contact Vytronix Ltd
The water supply is not
sufficient
Increase water pressure, check for blockages
and / or change the large pipe.
Pump seals worn
Contact Vytronix Ltd
The machine stops
The fuse has blown
Replace the fuse
Incorrect mains voltage
Unplug other appliances
Check that the mains voltage corresponds to the
specifications on the rating label.
Thermal sensor activated
Leave the machine to cool for 5 minutes
Partially blocked jet
Clean the jet with a needle and by spraying
water rearwardly through the jet
Fuse blown
Fuse too small
Replace it with a fuse with higher amp
consumption than the washer.
Increase in the amperage
Try without the extension cable
Pulsing machine
Air in inlet hose / pump
Allow machine to run with open trigger until
regular working pressure resumes.
Inadequate supply of water
generated
Increase water pressure, check for blockages
and / or change the large pipe.
Partially blocked jet
Clean the jet with a needle and by spraying
water rearwardly through the jet
Water filter blocked
Clean the filter
Folded pipe
Unfold the pipe
The machine turns on
and off by itself
Pump fuse and/or trigger not
working correctly
Contact Vytronix Ltd
No water supply
Connect the inflow water.
The machine is on
but no water comes
out
Water filter blocked
Clean the filter
Blocked jet
Clean the jet with a needle and by spraying
water rearwardly through the jet