2.
To change the recoat quantity, highlight "Quantity( l)", type in the desired value, and select "
" to accept the
value or "x" to cancel.
3.
Select "MAIN MENU" to return to the main process screen.
4.
Select "RECOAT" to initiate the recoat process.
Table 1.
Approximate injection quantity in microliters ( l) required for different length recoats.
The volume of recoat material required can be calculated as follows:
Diameters and length of the recoat in mm.
Select the Correct Mold Size for Your ARL Module
160 m
260 m
280 m
430 m
900 m
5 mm
0.07
0.20
0.25
0.86
4.00
10 mm
0.13
0.40
0.50
1.72
8.00
15 mm
0.20
0.60
0.75
2.58
12.00
20 mm
0.27
0.80
1.00
3.44
16.00
25 mm
0.34
1.00
1.25
4.30
20.00
30 mm
0.40
1.20
1.50
5.16
24.00
40 mm
0.54
1.60
2.00
6.88
32.00
Recoat
length
Vol
( l)
=
________
-
________ - length of recoat
4 4
(
)
π
D
2
mold
π
D
2
fiber
l
PTR-200-ARL Quick Reference Guide Version 1.2
Page 6