7
Electrical
Ratings
Rated Input Voltage
230 – 240V AC +- 10% - Single Phase
Frequency
50Hz
Maximum Power
7.4kW
Rated Current
32A @ 20°C maximum (permanent connection)
Standby Power
<6W
VMEV
Electrical
Protection
RDC-DD Protection fitted.
(Residual Direct Current
Detecting Device)
Type A RCCB is required to be
fitted at the switchboard.
RDC-DD fitted internally
6mA DC complying with IEC 62955.
Additional Internal Protection
Under/over voltage, short circuit, under/over
temperature, phase protection
Equipment Protection Class
Class 1
TECHNICAL SPECIFICATIONS
TROUBLESHOOTING
ERROR
CAUSE
SOLUTION
Charging cable cannot
be removed from
charger or vehicle
Interlocks in vehicle and
charger are engaged
Turn vehicle charging button off or unlock
vehicle if required.
Always unplug vehicle first then charger.
Charging takes a while
to start
Charger checking the
safety systems before
charging. This check can
take 20 secs
Normal operation.
Charging will start after 20 secs when
safety checks are complete.
Charging won’t start
after a previous use
VMEV Charger not
detecting the lead
and vehicle
Unplug the lead from the charger and
plug in again to reset. Always plug in
vehicle first then charger.