Vxl TC 15 Series User Manual Download Page 8

VXL Instruments Ltd

Itona TC15yy

 Hardware User’s Guide 

Installation                                                                                                                                                                                        8 

 

 

Installation 

This chapter describes hardware installation of the product. 

 

Step One: Unpack 

Unpack the unit taking care not to drop the product whilst removing from the packaging. 

The carton in which the product was shipped to you contains the following: 

 

 

Itona TC15yy Series Thin Client  

 

Power Adapter AC-DC 16V / 2.5A 

 

Power Cord   

 Pedestal 

 

 

DVI-I to VGA & DVI Cable ( Optional) 

 

Wall  / VESA Mounting Bracket ( Optional) 

 

Mouse (Optional  ) 

 

Hardware Installation Guide 

 

When you open the carton, if you find any discrepancy between the contents of the carton and the 
above list, contact the dealer or reseller from whom you have purchased the product, immediately. 

N

OTE

:

 

P

LEASE RETAIN THE ORIGINAL CARTON AND PACKING MATERIAL

.

 

T

HEY WOULD BE REQUIRED TO 

AVOID DAMAGE DURING TRANSIT 

(

IF REQUIRED IN FUTURE

). 

Step Two: Prepare 

1.  The site where you want to install the product must have the following 

 

 100~240V AC, 0.65A, 50/60 Hz, 3-pin power Inlet for Power Adapter.  

N

OTE

:

 

E

NSURE THAT THE POWER INLET PLUG IS PROPERLY REGULATED AND EARTHED

.

 

A

 FLOATING 

GROUND 

/

 CHASSIS COULD CAUSE AN ELECTRIC SHOCK

.

 

 

 

Fix the pedestals at the bottom of the Itona TC15yy. 

 

Well ventilated, clean, dry and dust free atmosphere 

 

Specified environmental conditions (refer to the section on specifications ) 

 

Table or desk of suitable size. 

 

2.  Place the product on the table in a location that provides quick and easy access to the power Inlet   

plug to shutdown the power in emergencies. 

3.  Ensure a minimum space of 2 inches (5 cm) on all sides of the unit for efficient convection cooling. 

 

 

 

 

 

 

9

9

Summary of Contents for TC 15 Series

Page 1: ...1 Itona TC15yy Hardware User s Guide VXL Instruments Ltd NO 17 House of Excellence Electronics City Hosur Road Bangalore 560 100 INDIA www vxl net...

Page 2: ...ecording for any purpose without the express written permission of the manufacturer Every effort has been made to make this guide as complete and as accurate as possible but no warranty or fitness is...

Page 3: ...entification number The full information of the associated label is as follows This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may...

Page 4: ...of the following chapters Introduction provides an overview of the product Installation contains the procedure to setup the hardware Specifications provides hardware mechanical electrical interface a...

Page 5: ...epare 8 Step Three Connect accessories and power 9 Caution 10 Step Four Connect to the Server 11 LAN connection through TCP IP 11 Specifications 12 Hardware 12 Mechanical 12 Environmental Operating 12...

Page 6: ...n Client computing They are aesthetically and ergonomically designed compact desktop providing simultaneous full screen connectivity to Windows and UNIX application servers a powerful business alterna...

Page 7: ...ction to a multi user Windows NT application server Also provided video display port USB compatible keyboard Mouse ports are available for quick setup and use Optional Features Wireless LAN Note The o...

Page 8: ...ct immediately NOTE PLEASE RETAIN THE ORIGINAL CARTON AND PACKING MATERIAL THEY WOULD BE REQUIRED TO AVOID DAMAGE DURING TRANSIT IF REQUIRED IN FUTURE Step Two Prepare 1 The site where you want to ins...

Page 9: ...ECTING ANY CABLES ENSURE POWER CABLE IS UNPLUGED FROM THE UNIT PLEASE USE 6A MIN 250V AC 0 75 sq mm H05VV F CERTIFIED POWER CORD Pictures below show the various connectors available on the rear panel...

Page 10: ...ur display unit to the video port 9 Connect USB devices to the USB ports 9 Connect external powered speakers to the audio output LINE OUT port 9 Connect microphone to the Microphone input port 9 Conne...

Page 11: ...00 1000 cable to the LAN port of the client Connect the other end to a LAN hub as shown in the figure below LAN Connection through TCP IP Press the power button to power up the Itona TC15yy The front...

Page 12: ...MM Networking 10 100 1000 Mbps Power supply External Adapter Display Support 1920x1200 60Hz 16 32 Bits Mechanical Itona TC15yy Height 190 mm Width 36 5 mm Depth 142 mm Weight 0 7 Kg max Environmental...

Page 13: ...RxD Video Port 15 pin D type female connector Pin Signal Pin Signal Pin Signal 1 Red 6 Red return GND 11 No Connection 2 Green 7 Green return GND 12 No Connection 3 Blue 8 Blue return GND 13 Horizont...

Page 14: ...Guide Cables and Connectors 14 Cables 10 100 1000 LAN Cable Cross Connection Without Hub Straight Connection With Hub TXD 1 3 RXD TXD 2 2 TXD RXD 3 1 TXD RXD 6 6 RXD RJ45 Pin RJ45 Pin TXD 1 1 TXD TXD...

Page 15: ...t is switched on 9 Ensure that the power cord is plugged into an AC outlet 9 Check the fuse in the power plug if available 9 There is no display though the power indicating LED glows Make sure the mon...

Reviews: