3.3.7
Noise Reduction
Description
Set the noise reduction between auto or fixed modes. In fixed mode, the noise reduction strength
can be adjusted.
HID Report Format
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Command = 5
Strength
N
R
Fields
Command
Set to 5
NR
Allowed values:
0: Auto mode
1: Fixed mode
Strength
Only valid when NR = 1. Allowed values:
0: Weakest
…
10: Strongest
Returns
No return value.
34
Revision 7
Vuzix Corporation