VULCANIC RADEB Instruction Manual Download Page 3

VULCANIC SAS

  

Instruction Manual

  

RADEB Type Radiator

 

81080-11 Rev A dated 27/06/13 - UTEN RADEB Radiator – Page 3/5 

-   Closure of the cover can be eased by the use of a non-corrosive grease whose flash point is 

greater than the maximum temperature reached by the box.  

-   Only apply electrical voltage to the installation after correctly closing the cover and 

reinstalling the opening locking device. 
 

4. 

SPECIAL CONDITIONS FOR SAFE USE IN POTENTIALLY EXPLOSIVE 
ENVIRONMENTS 

 
-  In natural convection, the heating elements must be placed horizontally. They must not be 

covered, so as to allow good air circulation. A free space of min. height 150 mm must be 
present above and below the heater bundle. 

-  In forced convection the heating elements can be placed in all positions. Nevertheless a 

minimum air speed must be guaranteed, and the electrical power supply must be slaved to 
the presence of this flow rate, in compliance with the conditions appearing on the 
manufacturer's contractual documents. 

-  When it exists the safety device must irreversibly cut the electrical power supply in the event 

of a fault, independently of that of the regulation, which necessitates human intervention to 
rest the installation after seeking the cause of the tripping out. Its setting is a maximum of 
195°C in class T3 and 130°C in class T4. Its interpretation must have fast, positive action; it 
must act directly on the radiator's electrical power supply, and must not be relayed by 
software. Failing this the safety circuit must have a minimum integrity level of SIL 1 as 
required by standard EN 50495. 

-  When the radiator sub-assembly includes a device to limit the surface temperature of its 

heating elements, this must be duplicated by the safety device described above. The limiting 
device is preset by VULCANIC to a setting that avoids the surface of the elements reaching a 
temperature of 195°C en class T3 and 130°C in class T4, in the most unfavourable normal or 
accidental operating conditions. This setting depends on the response time and differential of 
this device. 

-  In no case must the adjustment of the limiting and safety settings, done in the VULCANIC 

factories, be modified.  

-  In the absence of a temperature safety device, the user must provide monitoring of the 

supply voltage (which must not exceed the rated voltage by more than 10%), and the 
ambient temperature of the box (which must not exceed 40°C or 60°C depending on the 
model). 
The quality of the atmosphere in which the radiator is installed must be compatible with the 
austenitic stainless steel making up the sheath of the heating elements, so as not to damage 
them by corrosion. 

-  The specifications of installation standard IEC/EN 60079-14 must be complied with (in 

particular for monitoring of the radiator electrical insulation), as well as the current national 
standards. A fall in insulation could be a forewarning of loss of sealing of the heating 
elements, which necessitates an immediate switching off of the electrical power supply. 

-  The terminal box cover must not be opened in a potentially explosive atmosphere  

 

5. 

ELECTRICAL CONNECTION 

 
This connection must take place when the voltage is switched off. 
5-1 - Removing the cover: Remove the 4 fixing screws and extract the cover. 
5-2 - After introducing the cable through the gland connect the two or three phases to the 

terminals according to the diagram attached to the equipment.  

 

Warning: These electrical couplings are generally made in the VULCANIC factories. 
Modifying them is formally prohibited. 

 
 
 
 

5-3 - The internal and external earth terminals must be connected to the installation earth. 