S T E A M
F-32295 (05/10)
VSX5G
GAS COUNTER CONVECTION STEAMER
NOTE:
In line with its policy to continually improve its products, Vulcan reserves the right to change materials and specifications without notice.
SERVICE CONNECTIONS:
Unless otherwise specified, Field Wire Electrical Connection to
be 120/60/1 with grounding wire. Furnish with 6 foot cord with
3 prong plug. Maximum amps 2.0.
DRAIN:
1" (25 mm) IPS O.D. piped to open floor drain. No solid
connection. 24" length before open air gap opening (no bends
or elbows).
GAS CONNECTION:
3
⁄
4
" (19 mm) IPS supply line required.
GENERATOR WATER:
3
⁄
8
" (10 mm) O.D. tubing at 20-60 PSI
(136-480 kPa).
CONDENSING WATER:
3
⁄
8
" (10 mm) O.D. tubing at 20-60 PSI
(136-480 kPa).
WATER QUALITY STATEMENT:
The fact that a water supply is potable is no guarantee that it is
suitable for steam generation. Your water supply must be within these
general guidelines:
SUPPLY PRESSURE
20 - 60 psig
HARDNESS*
less than 3 grains
SILICA
less than 13 ppm
TOTAL CHLORIDE
less than 4.0 ppm
pH RANGE
7-8
UN-DISSOLVED SOLIDS
less than 5 microns
* 17.1 ppm = 1 grain of hardness
Other factors affecting steam generation are iron content, amount
of chloridation and dissolved gases. Water supplies vary from state
to state and from locations within a state. Therefore it is necessary
that the local water treatment specialist be consulted before the
installation of any steam generating equipment.
IMPORTANT:
1. A pressure regulator sized for this unit is included. Natural gas 4"
W.C., propane gas 11" W.C.
2. Gas line connecting to unit must be
3
⁄
4
" or larger. If flexible
connectors are used, the inside diameter must be at least the
same as the
3
⁄
4
" iron pipe and rated for the correct gas input.
3. An adequate ventilation system is required for commercial cooking
equipment. Information may be obtained by writing to the National
Fire Protection Association, Batterymarch Park, Quincy, MA
02289. When writing, refer to NFPA No. 96.
4. These units are manufactured for installation in accordance with
ANSZ223.1A (latest edition), National Fuel Gas Code. Copies may
be obtained from the American Gas Association, 1515 Wilson
Blvd., Arlington, VA 22209.
5. Clearance:
Combustible
Non-Combustible
Rear
6"
6"
Left Side
3"
3"
Right Side
8"
8"
NOTE:
• Dimensions which locate the above connections have a tolerance
of + or - 3" (+ or - 75mm). Normal dimensions are in inches.
Dimensions in ( ) are in millimeters.
• Installation of backflow preventers, vacuum breakers and other
specific code requirements is the responsibility of the owner and
installer. It is the responsibility of the owner and installer to comply
with local codes.
• Do not use plastic drains.
• Do not connect this unit to a ground-fault circuit-interrupter (GFCI)
125-volt, single-phase, 15- and 20-ampere receptacle. Electronic
burner ignition systems are prone to nuisance tripping and
possible ignition failure.
• This appliance is manufactured for commercial installation only
and is not intended for home use.