VSX42E SERIES

ELECTRIC HEATED CONVECTION STEAMER
ON CABINET BASE WITH 24 QT. TILTING KETTLE

WATER QUALITY STATEMENT:
The fact that a water supply is potable is no guarantee that it is suitable
for steam generation. Your water supply must be within these general
guidelines:

SUPPLY PRESSURE

20 - 60 psig

HARDNESS*

less than 3 grains

SILICA

less than 13 ppm

TOTAL CHLORIDE

less than 4.0 ppm

pH RANGE

7-8

UN-DISSOLVED SOLIDS

less than 5 microns

* 17.1 ppm = 1 grain of hardness

Other factors affecting steam generation are iron content, amount of
chloridation and dissolved gases. Water supplies vary from state to state
and from locations within a state. Therefore it is necessary that the local
water treatment specialist be consulted before the installation of any
steam generating equipment.

SERVICE CONNECTIONS:

Electric Connection: Junction box for electrical connection
for boiler heat.

Electric Connection for Controls: 120/60/1, 300 watt maxi-
mum, power supply with grounding wire required. (For other
than 120 volt supply, consult factory for location of this
connection.

Drain: Condenser box, compartment and boiler 1

1

/

4

" NPT

(Provide an open air gap type drain within 12" of condenser box
and for best results at a distance so that steam vapors will not
enter the steamer from underneath the control area. Do not
connect solidly to any drain connection.)

Cold Water Connection: 

3

/

8

" NPT for boiler feed. Inlet water

pressure between 20 and 80 psi.

Cold Water Connection: 

3

/

8

" NPT for condensate box. Inlet

water pressure between 20 and 80 psi.

Water:  For swing faucet, (single) (dual) temperature 

1

/

4

" IPS

tailpiece.

Steam Take-Off Connection:

3

/

4

" NPT.

NOTE:

• Dimensions which locate the above connections have a tolerance of

+ or -3" (+ or -75 mm).

• Installation of backflow preventers, vacuum breakers and other spe-

cific code requirements is the responsibility of the owner and installer.
It is the responsibility of the owner and installer to comply with local
codes.

• Plastic drains are not recommended due to inherent limited tempera-

tures of the plastic. Boiler purge temperatures may exceed 180

°

F. The

installer may be required to provide means to reduce boiler purge
water temperature to be that of the condensate temperature of 140

°

F

or less.

• This appliance is manufactured for commercial installation only and is

not intended for home use.

BRIMFUL CAPACITIES (In 4 oz servings):

Working capacity 70 to 80% of brimful depending on model.
24 quarts/6 gallons/23 liters/192 servings

STEAM FLOW RATE AT 10 PSIG AT THE KETTLE

Fast Boil

Medium Boil

Slow Boil

12 minutes

20 minutes

30 minutes

lbs/hr

kg/hr

lbs/hr

kg/hr

lbs/hr

kg/hr

6 gallons

39

18

21

10

14

6

NOTE:
1. The energy required to bring 70

°

F water to 212

°

F.

2. 1 boiler horsepower (BHP) = 34.5 lbs. of steam per hour.

Total

NOMINAL AMPS PER LINE

Conn.

Three Phase

Single Phase

KW

208

240

480

208

240

24

66

57.8

28.9

115.4

100

36

99.9

86.6

43.3

42

116.6

48

N/A

115

58

PAN CAPACITIES (Per compartment)

MODEL

1" deep

2

1

/

2

" deep

4" deep

VSX42ET

6

3

2

VSX42E5

10

5

3