![Vulcan-Hart VI2 Service Manual Download Page 6](http://html1.mh-extra.com/html/vulcan-hart/vi2/vi2_service-manual_1056585006.webp)
INDUCTION COOKERS - GENERAL
6
SPECIFICATIONS
MODEL
VOLTAGE
PLUG
TYPE
MAX.
AMPS
BREAKER
SIZE
VI2
208/60/1
220/240/60/1
6-20P
10.6
9.1/9.1
15
15
VI3
208/60/1
220/240/60/1
6-20P
14.6
12.3/12.5
15
15
VI22
208/60/1
220/240/60/1
6-30P
21.2
18.2/18.2
30
30
VI23
208/60/1
220/240/60/1
6-30P
25.2
21.4/21.6
30
30
VI33
208/60/1
220/240/60/1
6-30P
29.2
24.6/25.0
30
30
CLEANING
WARNING: DISCONNECT ELECTRICAL POWER
BEFORE CLEANING.
Clean the ceramic cooktop surface by using a cloth
moistened in warm water, or a solution of detergent
and warm water. For stubborn stains, ScotchBrite or
a soft paste of cleanser may be used; do not use
abrasive materials or harsh scouring action because
this could damage the surface.
Snap out air filters located on the bottom of the
cooktop and wash them in a sink. Dry filters before
reinstalling.
NOTE: Do not operate without filters in place. Filters
must be kept clean to prevent unit from overheating.
Keep area around unit clear to insure proper air
circulation.