VHXD SERIES

DIRECT STEAM CONVECTION STEAMERS
ON CABINET BASE

SERVICE CONNECTIONS

STEAM SUPPLY: 

 3

/

4

" NPT for 10 - 50 psi direct steam.

ELECTRICAL CONNECTION FOR CONTROLS: 120/60/1, 300
watt maximum, power supply with grounding wire
required. (For other than 120 volt supply consult factory for
location of this connection.)

DRAIN: Condenser box, compartment and boiler, 1

1

/

4

" NPT.

Provide an open air gap type drain within 12" of condenser box
and for best results at a distance so that steam vapors will not
enter the steamer from underneath the control area. Do not
connect solidly to any drain connection.

COLD WATER CONNECTION: 

1

/

8

" NPT for condensate box.

Inlet water pressure between 20 and 60 psi.

STEAM TAKE-OFF CONNECTION: 

3

/

4

" NPT.

NOTE:

• Dimensions which locate the above connections have a tolerance of +

or -3" (+ or -75 mm).

• Installation of backflow preventers, vacuum breakers and other spe-

cific code requirements is the responsibility of the owner and installer.
It is the responsibility of the owner and installer to comply with local
codes.

• Plastic drains are not recommended due to inherent limited tempera-

tures of the plastic. Boiler purge temperatures may exceed 180°F. The
installer may be required to provide means to reduce boiler purge water
temperature to be that of the condensate temperature of 140°F or less.

• This appliance is manufactured for commercial installation only and is

not intended for home use.