VHXD SERIES
DIRECT STEAM CONVECTION STEAMERS
ON CABINET BASE
SERVICE CONNECTIONS
STEAM SUPPLY:
3
/
4
" NPT for 10 - 50 psi direct steam.
ELECTRICAL CONNECTION FOR CONTROLS: 120/60/1, 300
watt maximum, power supply with grounding wire
required. (For other than 120 volt supply consult factory for
location of this connection.)
DRAIN: Condenser box, compartment and boiler, 1
1
/
4
" NPT.
Provide an open air gap type drain within 12" of condenser box
and for best results at a distance so that steam vapors will not
enter the steamer from underneath the control area. Do not
connect solidly to any drain connection.
COLD WATER CONNECTION:
1
/
8
" NPT for condensate box.
Inlet water pressure between 20 and 60 psi.
STEAM TAKE-OFF CONNECTION:
3
/
4
" NPT.
NOTE:
• Dimensions which locate the above connections have a tolerance of +
or -3" (+ or -75 mm).
• Installation of backflow preventers, vacuum breakers and other spe-
cific code requirements is the responsibility of the owner and installer.
It is the responsibility of the owner and installer to comply with local
codes.
• Plastic drains are not recommended due to inherent limited tempera-
tures of the plastic. Boiler purge temperatures may exceed 180°F. The
installer may be required to provide means to reduce boiler purge water
temperature to be that of the condensate temperature of 140°F or less.
• This appliance is manufactured for commercial installation only and is
not intended for home use.