TROUBLESHOOTING
TROUBLESHOOTING
Symptom
Possible Cause
Cabinet not operating.
1.
Cabinet not connected to power source or circuit breaker tripped.
2.
Cabinet lighted power switch not ON or malfunctioning.
Ground Fault Circuit Indicator (GFCI)
tripped.
1.
Shorted heating element.
2.
Pinched/damaged wiring (heating elements or fan).
3.
Damaged power cord.
Cabinet connected to power, switch is
ON, circuit breaker is ON but cabinet not
heating.
1.
Heating element malfunction.
2.
Temperature controller malfunction.
Cabinet not heating properly.
1.
Door not sealing properly.
2.
Fan not circulating air or malfunction.
3.
Temperature controller needs calibrating or malfunction.
Fan not operating
1.
Temperature controller not supplying power to fan (malfunction).
2.
Fan wiring not connected or malfunction.
3.
Fan not circulating air or malfunction.
Error codes, E01, E02, or E03.
1.
Moisture present at the top of the cabinet
near the control board.
1.
Fan mounted to top cover blocked off.
2.
Fan mounted to top cover not functioning.
3.
Fan mounted to top cover missing.
ERROR CODES
Code
Description
Correction
E01
Displays when controller detects and
open temperature sensor
E02
Displays when controller detects a
shorted temperature sensor.
E03
RH Display is ON and there is a short
10 RH error.
VHU INSULATED HUMIDIFIED CABINETS - TROUBLESHOOTING
F45642 (0217)