ELECTRICAL DATA CHARTS

VR RANGES WITH STANDARD OVENS OR VS RANGES WITH CABINET BODY

"N/A" RANGES NOT AVAILABLE 480 VOLT

      

 3 PHASE LOAD

NOMINAL AMPS PER LINE WIRE

TOTAL KW PER PHASE

3 PHASE

1 PHASE

KW

208V 240V 480V

208V

240V

480V

208V 240V 480V

MODEL

CONN. X-Y

Y-Z

X-Z

X

Y

Z

X

Y

Z

X

Y

Z

XYZ XYZ XYZ

VR1,2,5

21.7

7.7

5

9

70

53

58

60

46

51

30

23

25

104

90

45

VR1,2,5 / VB73

27.7

10.7

8

82

78

71

71

68

61

133

115

VS,VM1,2,5

15

5

5

5

42

42

42

36

36

36

18

18

18

72

63

31

VS,VM1,2,5 / VB73

21

8

8

54

67

54

47

58

47

101

88

VR3,6,7

20.7

7.7

5

8

65

53

54

57

46

47

28

23

24

99

86

43

VR3,6,7 / VB73

26.7

10.7

8

78

78

67

68

68

58

128

111

VS,VM3,6,7

14

5

5

4

38

42

38

33

36

33

16

18

16

67

58

29

VS,VM3,6,7 / VB73

20

8

8

50

67

50

43

58

43

96

83

VR4

18.7

6.7

4

8

61

45

50

53

39

43

19

27

22

90

78

39

VR4 / VB73

24.7

9.7

7

8

74

70

63

64

60

54

27

30

33

119

103

N/A

VS,VM4

12

4

4

4

33

33

33

29

29

29

14

14

14

58

50

25

VS,VM4 / VB73

18

7

7

46

58

46

40

51

40

87

75

480 Volt Only:

VR1,2,5 / VB73

21.7

7.7

11

9

30

34

36

N/A

VR3,6,7 / VB73

26.7

7.7

11

8

28

34

34

N/A

VS,VM1,2,5 / VB73

21

5

11

5

18

29

29

44

VS,VM3,6,7 / VB73

20

5

11

4

16

29

27

42

VR4 / VB73

24.7

6.7

10

8

27

30

33

N/A

VS,VM4 / VB73

18

4

10

4

14

25

25

38

VR RANGES WITH CONVECTION OVENS

       3 PHASE LOAD

NOMINAL AMPS PER LINE WIRE

TOTAL KW PER PHASE

3 PHASE

       1 PHASE

KW    208V,240V & 480V

208V

240V

480V

208V 240V

MODEL

CONN. X-Y

Y-Z

X-Z

X

Y

Z

X

Y

Z

X

Y

Z

XYZ XYZ

VR1C,2C,5C

22

6.2

6.2

9.6

66

51

66

57

45

57

29

22

29

106

92

VR1C,2C,5C/VB73

28

9.2

9.2

9.6

78

76

78

68

66

68

34

33

34

135

117

VR3C,6C,7C

21

6.2

6.2

8.6

62

51

62

54

45

54

27

22

27

101

87

VR3C,6C,7C/VB73

27

9.2

9.2

8.6

74

76

74

64

66

64

32

33

32

130

112

VR4C

19

5.2

5.2

8.6

58

43

58

50

37

50

25

19

25

91

79

VR4C/VB73

25

8.2

8.2

8.6

70

68

70

61

59

61

30

29

30

120

104

VEX AND VMX RANGES

       3 PHASE LOAD

NOMINAL AMPS PER LINE WIRE

TOTAL KW PER PHASE

3 PHASE

1 PHASE

KW

208V 240V 480V

208V

240V

480V

208V 240V 480V

MODEL

CONN. X-Y

Y-Z

X-Z

X

Y

Z

X

Y

Z

X

Y

Z

XYZ XYZ XYZ

VEX,VMX1

5

2.5

2.5

11

21

11

9

18

9

4.5

9.0

4.5

24

21

10.4

VEX2,VMX2

5

24

21

10.4

VEX3,VMX3

4

2

2

8

17

8

7

14

7

3.6

7.2

3.6

19

17

8.3

"VB73" in above charts denotes an electric elevated broiler installed over the range.

Summary of Contents for VEX

Page 1: ...RT COMPANY P O BOX 696 LOUISVILLE KY 40201 0696 TEL 502 778 2791 INSTALLATIONAND OPERATION MANUAL FOR ELECTRIC HEAVY DUTY RANGES MODELS VR VS VM VEX VMXAND VRC VR SERIES FORM 30820 6 93 Formerly 11268...

Page 2: ...2...

Page 3: ...y performance The manufacturer suggests that you thoroughly read this entire manual and carefully follow all of the instructions provided DESCRIPTION PAGE INDEX 3 VULCAN RANGE CONFIGURATIONS 4 GENERAL...

Page 4: ...VS2 VR3 VR6 VM3 VM6 VS3 VS6 VR5 VM5 VS5 VR4 VM4 VS4 VR3 VR6 VM3 VM6 VS3 VS6 SHOWN WITH OPTIONAL HIGH SPEED ELEMENTS VR7 VS7 VM7 VRC SERIES VS SERIES VULCAN RANGE CONFIGURATIONS VR1C VR2C VR3C VR6C VR5...

Page 5: ...5 VEX1 VMX1 VMX3 VEX3 VMX2 VEX2 VM1 VM2 VULCAN RANGE CONFIGURATIONS PL 51130 2...

Page 6: ...t center and right VM4 6 91 2 dia round French hot plates VM5 36 wide griddle with front grease trough VM6 2 91 2 dia round French hot plates at left and 2 12 x 24 all purpose plates at center and rig...

Page 7: ...n option All VR and VRC ranges with full size ovens VS cabinet base or VM modular ranges will have two drawers in the front of the range under the cooking top area The left hand drawer is a baffled gr...

Page 8: ...the range will be installed is level If the base is not level it must be levelled before installing the range ELECTRICAL CONNECTIONS WARNING ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE A...

Page 9: ...34 36 N A VR3 6 7 VB73 26 7 7 7 11 8 28 34 34 N A VS VM1 2 5 VB73 21 5 11 5 18 29 29 44 VS VM3 6 7 VB73 20 5 11 4 16 29 27 42 VR4 VB73 24 7 6 7 10 8 27 30 33 N A VS VM4 VB73 18 4 10 4 14 25 25 38 VR...

Page 10: ...EN 3 PHASE LOAD NOMINAL AMPS PER LINE WIRE TOTAL KW PER PHASE 3 PHASE 1 PHASE KW 220 380V 240 415V MODEL CONN X N Y N Z N X Y Z X Y Z X Z VR1C 2C 5C 22 6 2 6 2 9 6 33 25 33 34 26 34 34 60 VR1C 2C 5C V...

Page 11: ...VTM6 element rated at 5 KW Indicator light with without VEX2 VEX6 VMX2 next to thermostat is ON when thermostat trough VMX6 VR2C VR6C calls for heat and goes OFF when VS2 VS6 desired temperatire is re...

Page 12: ...dampened with a grease solvent Wipe with a clean damp cloth then dry thoroughly Seasoning The cast iron surface plates must be seasoned To do this grease top then turn element switches to LO or therm...

Page 13: ...n using rack and deck at the same time rotate foods halfway through cooking cycle When baking on the rack it may be necessary to set the bottom 3 heat switch at HI Preheat oven Set top and bottom 3 he...

Page 14: ...e 3 heat switches be set to the HI position in order to preheat the oven to the desired temperature it is necessary for some baking products to turn the 3 heat switch controlling the top elements to t...

Page 15: ...d parts with a damp cloth Stubborn soils may be removed with a detergent Rinse thoroughly and dry with a soft clean cloth Never use abrasive cleaners scrapers or steel wool on stainless steel parts 5...

Reviews: