INSTALLATION

Before installing, verify the electrical service
agrees with the specifications on the rating
plate located on the lower rear of the cart. If
the electrical service does not agree with the
rating plate, do not proceed with installation.
Contact your dealer or local Vulcan-Hart
service technician immediately.

Fig. 2

UNPACKING

The APPLIANCE was inspected before leaving
the factory. The transportation company
assumes full responsibility for safe delivery
upon acceptance of the shipment.
Immediately after unpacking, check for
possible shipping damage. If the APPLIANCE
is damaged, save packing material and
contact the carrier within 15 days of delivery.
Check the delivery documentation for damage
reporting contacts and time limits.

Carefully unpack and place in a work-
accessible area as near the installation
position as possible.

1. Open the door and carefully remove any

packaging materials and the retaining
straps that hold the wire plate racks
(VB) or tray slides and tray slide upright
side supports (VBP/VHP).

2. Remove all scratch protective film from

the cabinet.

3. On banquet carts, lift the plate racks

into position on the side brackets.

4. On food holding and transport cabinets,

remove cardboard element cover
protector from cabinet bottom.

Remove adjustable tray slides from box.

Remove the tray slide supports and
install them in the cabinet.

a. Hook the openings in the flat flange of

the support over two vertical carriage
bolts on the interior of the cabinet.

b. Make sure all flanges on the four

supports face the door opening.

Install tray slides in the cabinet.

Make sure the hook on the end of the
tray slide is up.

LOCATION

For efficient cabinet operation, choose a
location that will provide easy loading and
unloading without interfering with the final
assembly of food orders.

Fig. 3

The installation location must allow adequate
clearances for servicing and proper operation.

1

POWER/HEAT

2

OFF

3

4 5 6 7

8

9

10

NSF

®

°F

20

60

80

10

0

12

0

140

150

160 170 180

190

20

0

21

0

220

0

20

40

50

60

70

80

90

100

105

°C

HOLDING AND

TRANSPORT

SYSTEM

Leave adequate clearance 

for ease of loading and unloading.

Summary of Contents for V SERIES VBP13I ML-126359

Page 1: ...126359 VBP15I ML 126360 VBP77I ML 126361 VBS7 ML 138032 VBS15 ML 138033 VHDP5 ML 138035 VDW3 ML 138036 VB90 ML 126548 VB96 ML 126550 VB150 ML 126552 VB200 ML 138034 For additional information on Vulc...

Page 2: ...YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS ORANYOTHERAPPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTER ATION SERVICE OR MAINTENANCE C...

Page 3: ...or full size steam table pans of various depths The cabinets will also accommodate the 1 1 or 2 1 gastronorm pan Model VHP Holding and Transport Cabinets provide an efficient means of transporting ho...

Page 4: ...ate racks VB or tray slides and tray slide upright side supports VBP VHP 2 Remove all scratch protective film from the cabinet 3 On banquet carts lift the plate racks into position on the side bracket...

Page 5: ...ational Electrical code and or other local electrical codes The cord and plug supplied is a suitable durable cord with molded plug and is provided with a proper strain relief Appliances equipped with...

Page 6: ...5 1 60 5 15 208 240 2 7 6 15 VHP15 VHP20 110 120 10 1 60 5 15 208 240 5 4 6 15 VB90 VB96 110 120 16 6 1 60 5 20 VB150 VB200 208 240 9 0 6 20 Disconnect electrical power to the machine and follow Locko...

Page 7: ...POWER HEAT 2 OFF 3 4 5 6 7 8 9 10 NSF F 20 6 0 80 100 1 2 0 140 150 160 170 180 1 9 0 200 2 1 0 2 2 0 0 20 40 50 60 70 80 90 100 105 C POWER INDICATOR LIGHT HEAT INDICATOR LIGHT FULL RANGE THERMOSTAT...

Page 8: ...rature in heated appliance will fluctuate as the heating elements cycle on and off 6 Monitor the food product to ensure proper temperatures Appliance Temperatures The greater the thermostat setting nu...

Page 9: ...machine and follow Lockout Tagout procedures before cleaning Clean appliance interior with mild soap and water whenever a food spill occurs Never use harsh chemicals or abrasive pads to clean applian...

Page 10: ...asket Check door gasket for damage If adjustment is needed contact your Authorized Vulcan Hart Servicer Compartment does Defective heating coil Contact your authorized service provider not heat proper...

Page 11: ...S THERMOSTAT POWER HEATING ELEMENT POWER CONNECTION 120V 1PH 60 Hz 208 240V 1PH 60 Hz HEATING ELEMENT A BLACK BLACK WHITE WHITE GREEN RED A POWER R VB48 VB72 VB90 VB96 VB150 VBP5I VBP7I VBP13I VBP15I...

Page 12: ...12 V SERIES VBP77I Wiring Diagram THERMOSTAT POWER CONNECTION 120V 1PH 60 Hz 208 240V 1PH 60 Hz BLACK THERMOSTAT BLACK BLACK WHITE GREEN HEATING ELEMENT HEATING ELEMENT POWER R POWER A POWER R POWER A...

Page 13: ...13 V SERIES THERMOSTAT POWER HEATING ELEMENT POWER CONNECTION 120V 1PH 60 Hz 208 240V 1PH 60 Hz A BLACK WHITE WHITE GREEN RED A VHP3 VHP7 VHP8 Wiring Diagram...

Page 14: ...XCEPT 2 90 WP 149 851800 606 HANDLE SIDE LIFT 1220 3 7 8 1826 7 WP 108 851800 134 HINGE DOOR WP 111 851800 18 HOLDER PROBE THERMOMETER WP 093 851800 29 HOLDER PROBE THERMOSTAT WP 089 851800 32 KNOB TH...

Page 15: ...15 V SERIES 9 07 PRINTED IN U S A NOTES...

Page 16: ...this model contact the Vulcan Hart Service Agency in your area refer to our website www vulcanhart com for a complete listing of Authorized Service and Parts depots When calling for service the follo...

Reviews: