3.
Adjust the motor position until the blower is
parallel to and 1/4 inch away from the motor
mounting plate. Check for squareness of the
blower to the motor mounting plate at the top,
bottom, left and right of the blower.
A.
If the blower is square then tighten motor
mounting bolts and proceed to Step 4.
B.
If the blower is not square continue
adjusting until proper spacing is achieved
then tighten motor mounting bolts.
NOTE:
If necessary, place shims between motor and
frame.
Fig. 46
4.
Reverse the procedure to install.
DOOR ADJUSTMENT
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
1.
Check the doors to make sure they have an equal
gap between them and that the vertical edge of
the door is parallel to the vertical door seal. If the
doors are not positioned in this manner, adjust
the doors as described.
Fig. 47
2.
3.
Loosen the screws that secure the upper door
bearings and related hardware, just enough to
allow door movement.
Fig. 48
SG SERIES GAS CONVECTION OVENS - SERVICE PRODCEDURES AND ADJUSTMENTS
Page 21 of 31
F45525 (0814)