LEVELING

Place a carpenter's level on top of the charbroiler.  Level the charbroiler front to back and side to side
by turning the adjustment screw at the bottom of each leg.

GAS CONNECTIONS

Gas supply connections and any pipe joint compound must be resistant to the action of propane gases.

Location of the gas inlet is at the rear on the right side.  Codes require that a gas shutoff valve must
be installed in the gas line ahead of the charbroiler.

Connect gas supply.  Make sure the pipes are clean and free of obstructions.

Charbroilers are equipped with fixed burner orifices for use with natural or propane gas and no
adjustments are necessary.

Natural gas pressure regulators are preset for an outlet pressure of 3.7" W.C. (Water Column); propane
gas pressure regulators are preset for 10" W.C.

WARNING:  PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS.
USE SOAP AND WATER SOLUTION.  DO NOT USE AN OPEN FLAME.

After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.

TESTING THE GAS SUPPLY SYSTEM

When gas supply pressure exceeds 

1

/

2

 psig (3.45 kPa), the charbroiler and its individual shutoff valve

must be disconnected from the gas supply piping system.

When gas supply pressure is 

1

/

2

 psig (3.45 kPa) or less, the charbroiler should be isolated from the gas

supply system by closing its individual manual shutoff valve.

VENTILATION

It is recommended that the exhaust fumes be ventilated to the outside of the building through a
ventilation system installed by qualified personnel.

Information on the construction and installation of ventilating hoods may be obtained from the standard
for "Vapor Removal from Cooking Equipment," NFPA No. 96 (latest edition), available from the
National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

Summary of Contents for MGCB18 ML-103821

Page 1: ...AS CHARBROILERS MODEL MGCB18 ML 103821 MGCB24 ML 103822 MGCB29 ML 103823 MGCB34 ML 103825 VULCAN HART COMPANY P O BOX 696 LOUISVILLE KY 40201 0696 TEL 502 778 2791 FORM 31008 11 96 Formerly 990503 INSTALLATION OPERATION MANUAL ...

Page 2: ...HE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION ...

Page 3: ... 5 Leveling 7 Gas Connections 7 Testing the Gas Supply System 7 Ventilation 7 OPERATION 8 Controls 8 Before First Use 8 Lighting Instructions 8 Turning the Charbroiler On 9 Turning the Charbroiler Off 9 Using the Charbroiler 9 Grease Pan 9 Cleaning 10 MAINTENANCE 11 Lubrication 11 Service and Parts Information 11 ...

Page 4: ...ts do not agree do not proceed with the installation Contact your dealer or Vulcan Hart Company immediately UNPACKING This charbroiler was inspected before leaving the factory The transportation company assumes full responsibility for safe delivery upon acceptance of the shipment Immediately after unpacking check for possible shipping damage If the charbroiler is found to be damaged save the packa...

Page 5: ...al Fuel Gas Code ANSI Z223 1 latest edition Copies may be obtained from The American Gas Association Inc 1515 Wilson Blvd Arlington VA 22209 In Canada 1 Local codes 2 CAN CGA B149 1 Installation for Natural Gas Burning Appliances and Equipment latest edition 3 CAN CGA B149 2 Installation for Propane Burning Appliances and Equipment latest edition available from the Canadian Gas Association 55 Scar...

Page 6: ... 6 Fig 2 Fig 1 ...

Page 7: ...NG PRIOR TO LIGHTING CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS USE SOAP AND WATER SOLUTION DO NOT USE AN OPEN FLAME After piping has been checked for leaks all piping receiving gas should be fully purged to remove air TESTING THE GAS SUPPLY SYSTEM When gas supply pressure exceeds 1 2 psig 3 45 kPa the charbroiler and its individual shutoff valve must be disconnected from the gas supply pip...

Page 8: ...ll the upper front panel place panel above the lower front panel and slip upper panel down so it engages lower front panel Lighting the Pilot If the pilot goes out an automatic shutoff valve turns off the gas supply to the burners To relight the pilot follow these procedures 1 Turn the thermostats to the OFF position 2 Turn the main shutoff valve to OFF 3 Wait 5 minutes to allow gas which may have...

Page 9: ... F for best broiling results Then adjust the control knobs to the LO position to maintain the grid temperature between 575 F and 625 F Do not leave the burners on with knobs in the HI position for any extended period of time beyond the recommended preheat time or burn off time see CLEANING in this manual To minimize gas usage operate only those burners needed for the cooking load GREASE PAN Grease...

Page 10: ...om surfaces of grate with a wire brush to remove animal fats and carbonized grease 5 Clean channels on grates with a scraper 6 Remove grates from broiler Clean top surface of radiants with the wire brush They may be cleaned in place 7 Once a week after completing steps 1 6 remove the radiants Using a brush clean reflecting drip shield see Fig 1 of any dust or debris Once a week thoroughly clean th...

Page 11: ...hecked and lubricated periodically by your local service agency SERVICE AND PARTS INFORMATION To obtain service and parts information concerning this charbroiler contact the Vulcan Hart Service Agency in your area refer to listing supplied with the charbroiler or Vulcan Hart Company Service Department at the address or phone number shown on the front cover of this manual ...

Page 12: ... 12 FORM 31008 11 96 Formerly 990503 PRINTED IN U S A ...

Reviews: