Vulcan-Hart MG24CB Installation & Operation Manual Download Page 10

— 10 —

CLEANING

At least once a day, remove the grease pan, empty and wash it out in the same way you would any
cooking utensil.

"Burn off" the grease build-up on the grate daily or as dictated by use.    Always use insulated gloves
when handling grates or radiants to prevent burns.

CAUTION:  Do not cover the top of the grid grates during a burn-off operation.  Restricting the
air flow by covering the grid grates may cause them to warp.

The top grid grates and radiants are heavy.  They may break if dropped or bumped.

To "burn off" the grates:

1. Place grates on broiler with grid bars horizontal, facing down.

2. Turn control knobs to HI for approximately 45 minutes.

3. Turn broiler OFF and allow it to cool for 20 minutes.

4. Clean top and bottom surfaces of grate with a wire brush to remove animal fats and carbonized

grease.

5. Clean channels on grates with a scraper.

6. Remove grates from broiler.  Clean top surface of radiants with the wire brush.  They may be

cleaned in place.

7. Once a week, after completing steps 1-6, remove the radiants.  Using a brush, clean reflecting drip

shield (see Fig. 1) of any dust or debris.

Once a week, thoroughly clean the exposed surfaces of the broiler (sides, front and top grease trough)
with a damp cloth, then polish with a soft dry cloth.  A detergent may be used for cleaning.  To remove
discolorations, use a non-abrasive cleaner.

Burner air shutter openings must be kept clean.

Burner ports must be kept clean.  To remove burners:

1. Remove the top grates.

2. Remove the radiants.

3. Remove the burners.

Brush burner ports with a wire brush or clean ports with a sharp pointed metal instrument to ensure
open ports.

Reverse above procedure for reassembly.

Summary of Contents for MG24CB

Page 1: ...MG24CB MEDIUM DUTY GAS CHARBROILER COUNTERTOP MODEL MODEL MG24CB ML 114634 VULCAN HART COMPANY P O BOX 696 LOUISVILLE KY 40201 0696 TEL 502 778 2791 FORM 31025 3 97 INSTALLATION OPERATION MANUAL...

Page 2: ...E EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOR...

Page 3: ...5 Leveling 7 Gas Connections 7 Testing the Gas Supply System 7 Ventilation 7 OPERATION 8 Controls 8 Before First Use 8 Lighting Instructions 8 Turning the Charbroiler On 9 Turning the Charbroiler Off...

Page 4: ...requirements do not agree do not proceed with the installation Contact your dealer or Vulcan Company immediately UNPACKING This charbroiler was inspected before leaving the factory The transportation...

Page 5: ...dance with In the United States of America 1 State and local codes 2 National Fuel Gas Code ANSI Z223 1 latest edition Copies may be obtained from The American Gas Association Inc 1515 Wilson Blvd Arl...

Page 6: ...6 Fig 2 Fig 1...

Page 7: ...NG PRIOR TO LIGHTING CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS USE SOAP AND WATER SOLUTION DO NOT USE AN OPEN FLAME After piping has been checked for leaks all piping receiving gas should be f...

Page 8: ...e To install the front panel slide out drip pan replace front panel and install four screws in panel Lighting the Pilot If the pilot goes out an automatic shutoff valve turns off the gas supply to the...

Page 9: ...cooking time After this period of preheat grid temperatures will be in the range of 600 F for best broiling results Then adjust the control knobs to a lower position to maintain the grid temperature...

Page 10: ...m surfaces of grate with a wire brush to remove animal fats and carbonized grease 5 Clean channels on grates with a scraper 6 Remove grates from broiler Clean top surface of radiants with the wire bru...

Page 11: ...iodically by your local service agency SERVICE AND PARTS INFORMATION To obtain service and parts information concerning this charbroiler contact the Vulcan Hart Service Agency in your area refer to li...

Page 12: ...12...

Reviews: