Fig. 8
5.
Remove thermostat mounting screws (Fig. 8)
and bracket.
6.
Note and disconnect thermostat wiring.
Fig. 9
7.
Loosen packing nut (1, Fig. 10) and remove
holding nut (2, Fig. 10).
Fig. 10
8.
Remove thermostat bulb from clamp.
Fig. 11
9.
Remove thermostat assembly.
10. Reverse procedure to install.
Take care not to kink thermostat capillary when
installing. Wrap threads of packing nut with teflon tape
to prevent leakage.
HIGH LIMIT THERMOSTAT
Shut off the gas before servicing the
unit and follow lockout / tagout
procedures.
1.
2.
3.
4.
Remove high limit mounting bracket.
LG Series Fryer - REMOVAL AND REPLACEMENT OF PARTS