17
-
ELECTRICAL CONNECTIONS
Electrical and grounding connections must comply with the
applicable portions of the National Electrical Code and/or other local electrical
codes.
Disconnect the electrical power to the griddle and follow lockout /
tagout procedures.
Since the griddle top is not fused, you must connect to a fused circuit equipped with a
suitable disconnecting means as required by local authorities.
Electrical Connections
1. Remove the small junction box cover plate on the back of the unit. This exposes the
GTS clamshell griddle line leads.
2. Select a suitable knockout on the sides or bottom of the junction box.
3. Connect the griddle’s line leads to the supply wires with factory supplied wire connectors as shown
in the applicable wiring diagrams.
4. Push the excess wire into the junction box and replace the cover plate. Never operate griddle
without cover in place.
ELECTRICAL
SPECIFICATIONS
Model
No
Description
Voltage
Power
1
Phase
Draw
GTS12
‐
1
Front
Grease
Trough
Models
208
V
3.6
kW
17.3
A
GTS12
‐
2
240
V
3.6
kW
15
A
GTS12
‐
3R
Rear
Grease
Trough
Models
208
V
3.6
kW
17.3
A
GTS12
‐
4R
240
V
3.6
kW
15
A