REMOVAL AND REPLACEMENT OF PARTS
COVERS AND PANELS
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Control Panel
1.
Remove screws at top of control panel, and
rotate panel downward.
COMPUTER CONTROL, C MODEL
Fig. 6
2.
Disconnect wiring harness, then lift off panel.
NOTE:
The cooking control, control box, interface
board, and wiring harness are now accessible.
3.
Reverse procedure to install.
Basket Lift Covers
Shut off the gas
before servicing the unit and follow
lockout / tagout procedures.
All gas joints disturbed during
servicing must be checked for leaks. Check with a
soap and water solution (bubbles). Do not use an open
flame.
NOTE:
This procedure applies to fryers with
automatic basket lift option only.
1.
Remove basket assembly lift arms from support
rods.
2.
Remove screws securing upper cover to flue
wrap.
Fig. 7
A.
Lift upper cover over support rods, and
place cover to the side.
3.
Remove screws securing lower cover to motor
mounting base.
Fig. 8
4.
Reverse procedure to install.