— 3 —
F35641 (02-05)
EF SERIES GAS FRYERS
GENERAL
INTRODUCTION
Models
This service manual was written for:
EF3, EF4 and EF5 Gas Fryers.
INSTALLATION
Generally, installations are made by the dealer
or contracted by the dealer or owner. Detailed
installation instructions are included in the
Installation and Operation Manual, which is
sent with each fryer.
OIL FILTERING
Filtering instructions are included in the
Installation and Operation Manual.
OPERATION
Detailed operation instructions are included
with each fryer in the Installation and
Operation Manual.
CLEANING
Detailed cleaning procedures are included in
the Installation and Operation Manual.
LIGHTING PILOT
1. Turn thermostat OFF.
2. Turn gas control valve knob to OFF/PILOT.
Wait 5 minutes.
3. Push the gas control valve knob in.
4. While still holding knob in light the pilot
with a taper. Continue to depress knob
(approximately 30 seconds) until the pilot
remains lit after the knob is released. If
pilot does not remain lit, repeat steps 2, 3
& 4.
5. Turn gas control valve knob to ON.
6. If gas supply is interrupted, repeat steps
1-5.
SPECIFICATIONS
Gas Data
MODEL
NO. TUBES
BTU/HR
EF3
3
90,000
EF4
4
120,000
EF5
5
150,000
TOOLS
Standard
•
Hand tools (standard set)
•
VOM with AC current tester (any quality
VOM with a sensitivity of at least 29,000
ohms per volt can be used)
•
Gas test kit
•
Temperature tester (thermocouple type)
•
Manometer
Summary of Contents for ECONOFRY EF3 ML-52099