Fig. 12
NOTE:
Connector is located under cable shield.
3.
Disconnect position sensor connector (2, Fig.
13) from harness.
4.
Remove cable ties and position sensor cable
from cable shield.
5.
Remove two screws, nuts, and position sensor
(1).
6.
Reverse procedure to install.
Fig. 13
HEATING ELEMENT
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Parts may be hot. Use care when
handling them.
Do not sharply bend, kink, or clamp down
on high limit switch probe capillary tube or damage
may occur.
1.
If replacing left heating element:
A.
Remove nuts.
B.
Move temperature probe / clamps (1, Fig.
14) away from element.
Fig. 14
2.
If replacing right heating element:
A.
Remove nuts.
B.
Move high temperature switch probe /
clamps away from element.
3.
NOTE:
Each heating element assembly contains
three individual elements (six lead wire connections
total). Document wire connections.
4.
Disconnect heating element (2, Fig. 14) lead
wires.
5.
Remove screws and heating element.
CEF40/75 FRYER - REMOVAL AND REPLACEMENT OF PARTS
F45657 (0517)