C24EA FLOOR SERIES

ELECTRIC CONVECTION STEAMER

ON CABINET BASE

NOTE:

 In line with its policy to continually improve its products, Vulcan reserves the right to change materials and specifications without notice.

SERVICE CONNECTIONS:

ELECTRICAL CONNECTION:

 Single point supply 1

1

8

" (29 mm) dia.  

(

3

/

4

" conduit).

DRAIN:

 Condenser box, compartment and generator, 1

1

2

" NPT. 

(Provide an open air gap type drain within 12" of condenser box 
and for best results at a distance so steam vapors will not enter the 
steamer from underneath the control area. Do not connect solidly to 
any drain connection.)

GENERATOR WATER SUPPLY:

 

3

4

" (19 mm) male hose thread to 

generator, cold water flow rate .5 gpm @ minimum 20 to maximum  
60 psi. (138-414 kPa).

CONDENSING WATER SUPPLY:

 

3

4

" (19 mm) male hose thread to 

condenser, cold water flow rate .5 gpm @ minimum 20 to maximum  
60 psi. (138-414 kPa).

WATER QUALITY STATEMENT:

The fact that a water supply is potable is no guarantee that it is 
suitable for steam generation. Your water supply must be within these 
general guidelines:
 

SUPPLY PRESSURE

 

20 - 60 psig

 

HARDNESS*

 

less than 3 grains

 

SILICA

 

less than 13 ppm

 

TOTAL CHLORIDE

 

less than 4.0 ppm

 

pH RANGE

 

7-8

 

UN-DISSOLVED SOLIDS

 

less than 5 microns

 

*  17.1 ppm = 1 grain of hardness

Other factors affecting steam generation are iron content, amount 
of chloridation and dissolved gases. Water supplies vary from state 
to state and from locations within a state. Therefore it is necessary 
that the local water treatment specialist be consulted before the 
installation of any steam generating equipment.

NOTE:

•  Dimensions which locate the above connections have a tolerance 

of + or -3" (+ or -75 mm). Normal dimensions are in inches. 
Dimensions in ( ) are in millimeters.

•  Installation of backflow preventers, vacuum breakers and other 

specific code requirements is the responsibility of the owner and 
installer. It is the responsibility of the owner and installer to comply 
with local codes.

•  Do not use plastic drains.
•  This appliance is manufactured for commercial installation only 

and is not intended for home use.

MODEL

Phase

208 V

240 V

480 V

kW

Amps

kW

Amps

kW

Amps

C24EA6

17.2

81.25

17.2

79.1

17.2

N/A

17.2

48.2

17.2

51.3

17.2

21.4

C24EA10

25.6

121.2

25.6

110.4

25.6

N/A

25.6

71.2

25.6

67

25.6

31.8

NOTE:

 3ø is an unbalanced load, and amps listed is the max on any leg. Refer to the Installation and Operation Manual for further details.

10.5

(267)

TREATED

WATER

9.0

(230)

ELECTRICAL

16.7

(424)

UNTREATED

WATER

6.0

(152)

24.0

(610)

12.0

(305)

3.2

(82)

4.5

(115)

28.0

(712)

6 PAN 58.7

          (1490)

10 PAN 71.5

          (1823)

6 PAN 55.0

          (1397)

10 PAN 67.9

          (1730)

35.5

(901)

24.0

(609)

8.0

(203)

2.0

(51)

NO OPEN

DRAIN

23.9

(607)

DRAIN

29.8

(758)

CONDENSATE

BOX VENT

2.0

(51)

2.0

(51)

2.1

(53)

DRAIN

4.0

(102)

CONDENSATE

BOX VENT

COMPARTMENT PAN CAPACITY

MODEL

1"

2

1

2

"

4"

6"

C24EA6

6

3

2

1

C24EA10

10

5

3

2