TOOLS
•
Standard set of hand tools.
•
VOM with A/C current tester (any quality VOM
with a sensitivity of at least 20,000 ohms per volt
can be used).
•
Temperature tester (thermocouple type).
•
U-Tube or Digital Manometer.
•
Thread sealant suitable for use with natural or
propane gas.
•
Aluminum Foil Tape - McMaster Carr Part No.
7631421 or equivalent.
•
Adapter to test thermocouple, Johnstone Supply
Part No. H23-226 or equivalent.
Fig. 1
COMPONENT LOCATION
Front View 924RX
Fig. 2
1.
Pilot electric ignition system control switch (RX
only)
2.
Power cord (RX only)
3.
Thermostat
4.
Gas shut off valve (RX only)
5.
BASO® pilot safety valve
6.
Pilot flame adjustment
Top View 924RX
Fig. 3
1.
Burner assembly
2.
Electric igniter (RX only)
3.
Thermostat
4.
Orifice
5.
Thermostat capillary tube
6.
Pilot, igniter (RX only) and thermocouple
7.
BASO® pilot safety valve
8.
Pilot adjustment valve
Heavy Duty Gas Griddles - GENERAL
Page 5 of 19
F25383 (0219)