BUILT-IN FILTER SYSTEM FOR GBDF SERIES FRYERS
Model No.
2 Fryers
3 Fryers
4 Fryers
Width
Width
Width
G4BDF
31"
46
1
/
2
"
62"
G6BDF
42"
63"
84"
G8BDF
42"
63"
84"
BATTERY DIMENSIONS:
IMPORTANT
1. A combination valve with pressure regulator is provided with
this unit.
Natural Gas 4.0" (102 mm) W.C.
Propane Gas 10.0" (254 mm) W.C.
2. An adequate ventilation system is required for Commercial
Cooking Equipment. Information may be obtained by writing
to the National Fire Protection Association, Batterymarch
Park, Quincy, MA 02269. When writing refer to NFPA No. 96.
3. All models require a 6" (152 mm) clearance at both sides and
rear adjacent to combustible construction.
TOP VIEW
2G4BDF/
2G6BDF/
2G8BDF
SERIES
4. All models require a 16" (407 mm) minimum clearance to adjacent
open top burner units.
5. This appliance is manufactured for commercial installation only and
is not intended for home use.
SERVICE CONNECTIONS:
P1 1
1
/
4
" (32 mm) NPT common rear gas connection.
E1 115 volt cord & 5-15P NEMA plug supplied with fryers(filter pump).
GBDF KLEENSCREEN
PLUS®
FILTRATION SYSTEM
E1
P1
FRONT VIEW
2G4BDF/
2G6BDF/
2G8BDF
SERIES
SIDE VIEW
2G4BDF/
2G6BDF/
2G8BDF
SERIES
SEE CHART