BUILT-IN FILTER SYSTEM FOR GBDF SERIES FRYERS

Model No.

2 Fryers

3 Fryers

4 Fryers

Width

Width

Width

G4BDF

31"

   46

1

/

2

"

62"

G6BDF

42"

63"

84"

G8BDF

42"

63"

84"

BATTERY DIMENSIONS:

IMPORTANT

1. A combination valve with pressure regulator is provided with

this unit.

Natural Gas 4.0" (102 mm) W.C.

Propane Gas 10.0" (254 mm) W.C.

2. An adequate ventilation system is required for Commercial

Cooking Equipment. Information may be obtained by writing

to the National Fire Protection Association, Batterymarch

Park, Quincy, MA 02269. When writing refer to NFPA No. 96.

3. All models require a 6" (152 mm) clearance at both sides and

rear adjacent to combustible construction.

TOP VIEW

2G4BDF/
2G6BDF/

2G8BDF
 SERIES

4. All models require a 16" (407 mm) minimum clearance to adjacent

open top burner units.

5. This appliance is manufactured for commercial installation only and

is not intended for home use.

SERVICE CONNECTIONS:

P1 1

1

/

4

" (32 mm) NPT common rear gas connection.

E1 115 volt cord & 5-15P NEMA plug supplied with fryers(filter pump).

GBDF KLEENSCREEN 

PLUS®

FILTRATION SYSTEM

E1

P1

FRONT VIEW

2G4BDF/
2G6BDF/

2G8BDF
 SERIES

SIDE VIEW

2G4BDF/
2G6BDF/

2G8BDF
 SERIES

SEE CHART