WATER QUALITY STATEMENT:
The fact that a water supply is potable is no guarantee that it is suitable
for steam generation. Your water supply must be within these general
guidelines:
SUPPLY PRESSURE
20 - 60 psig
HARDNESS*
less than 3 grains
SILICA
less than 13 ppm
TOTAL CHLORIDE
less than 4.0 ppm
pH RANGE
7-8
UN-DISSOLVED SOLIDS
less than 5 microns
* 17.1 ppm = 1 grain of hardness
Other factors affecting steam generation are iron content, amount of
chloridation and dissolved gases. Water supplies vary from state to state
and from locations within a state. Therefore it is necessary that the local
water treatment specialist be consulted before the installation of any
steam generating equipment.
EQUIPMENT CLEARANCE:
Combustible
Non-Combustible
Side Walls & Rear Wall
6"
0"
CAPACITIES (in 4 oz. servings):
40 quarts / 10 gallons / 37.5 liters - 320 servings.
MODEL 1T4024G
40 QUART
2
/
3
JACKETED TILTING
KETTLE ON GAS BOILER BASE
SERVICE CONNECTIONS:
A
Gas Connection:
3
/
4
" NPT.
B
Electrical Connection for Controls: 120/60/1. 300 watt maximum,
power supply with grounding wire required. (Not furnished if optional
stepdown transformer is furnished.)
C
Drain: Condenser box, compartment and boiler, 1
1
/
2
" NPT. (Provide
an open air gap type drain within 12" of condenser box and for best
results at a distance so that steam vapors will not enter the steamer
from underneath the control area. Do not connect solidly to any drain
connection.
D
Cold Water Connections (2):
D1 Treated Cold Water Connection:
1
/
4
" NPT for boiler feed. Inlet
water pressure between 20 and 80 psi.
D2 Untreated Cold Water Connection:
1
/
4
" NPT for condensate
box. Inlet water pressure between 20 and 80 psi.
E
Water: For swing faucet, (single) (dual) temperature,
1
/
4
" tubing.
NOTE:
• Dimensions which locate the above connections have a tolerance of
+ or -3" (+ or -75 mm).
• Installation of backflow preventers, vacuum breakers and other specific
code requirements is the responsibility of the owner and installer. It is
the responsibility of the owner and installer to comply with local codes.
• Plastic drains are not recommended due to inherent limited tempera-
tures of the plastic. Boiler purge temperatures may exceed 180
°
F.
The installer may be required to provide means to reduce boiler
purge water temperature to be that of the condensate temperature of
140
°
F or less.
• This appliance is manufactured for commercial installation only and
is not intended for home use.