Specifications 

 

 

 

S400VA 

S1000VA  

S1500 VA 

Input Voltage 

12V DC 

Output Voltage 

230V AC +/- 5%; 50Hz 

Rated Output 
Power 

320W 

800W 

1200W 

Max. Output 
Power 

400VA 

1000VA 

1500VA 

Peak Surge 
Power (5s) 

600VA 

2000VA 

3000VA 

Power factor 

0.8 

Max Efficiency 

90% 

Protections 

Battery Deep Discharge

 (Low Voltage 

Disconnect / Reconnect); AC Short Circuit; Over 

Load; Reverse DC Polarity 

No Load Power 

Consumption 

<

 

2W

 (in 

Green Power 

status) 

< 6W 

< 4W

 (in 

Green Power 

status) 

Cooling 
Method 

Natural convection, heat dissipation via 

aluminium casing and heat sink; fan 

Available 

Versions 

Inverter 

Inverter;

 UPS 

w/ AC Battery 

Recharging 

Function

 

Inverter 

Transfer time 

---- 

12ms 

---- 

Size 

200x125x115 

mm; 2.0kg 

340x135x134 

mm; 3.8 kg 

365x195x155 

mm; 6.4 kg 

Accessories 

DC cables w/ cable shoe for battery connection 

Summary of Contents for S400VA

Page 1: ...de range of applications It will operate most televisions fans lamps personal computers small appliances and tools The inverter must have a greater power rating than the load it provides power to To g...

Page 2: ...s Battery Deep Discharge Low Voltage Disconnect Reconnect AC Short Circuit Over Load Reverse DC Polarity No Load Power Consumption 2W in Green Power status 6W 4W in Green Power status Cooling Method N...

Page 3: ...w Cable shoe Connect to 12V battery Red is positive Black Blue is negative 3 2 Front side a AC outlets Connect to 220V loads b Green Power switch S400VA S1500VA Energy saving enable Turn the switch ON...

Page 4: ...loose connection red 4 Installation 4 1 Where to install The power inverter should be installed in a location that meets the following requirements a Dry Do not allow water to drip or splash on the i...

Page 5: ...the negative terminal of the battery Tighten the screw to clamp the wires securely Caution Loose connections result in excessive voltage drop and may cause overheated wires and melted insulation Caut...

Page 6: ...loads If you are operating several loads from the power inverter turn them on separately after the inverter has been turned on This will ensure that the power inverter does not have to deliver the sta...

Page 7: ...move load Then switch the ON OFF switch back to ON 5 2 Empty battery indicator The indicator Empty indicates that the power inverter has shut itself down because of low input voltage This maybe becaus...

Page 8: ...en though their rated current draw is within the power inverter 7 2 Input voltage The power inverter will shut down if the input voltage drops below 10 5V This protects your battery from being overly...