1. INTRODUCTION
1.1. PRECAUTIONS, REQUIREMENTS, RECOMMENDATIONS
Detailed analysis of this documentation, as well as assembly and use of equipment, according to the descriptions contained therein, and following all safety requirements, is the basis for the
correct and safe operation of the device. Any other use that contradicts this instruction may cause accidents with serious consequences. Unauthorized personnel should have limited access
to the device, while the personnel should be properly trained. The term operational personnel refers to people, who, as the result of completed training, own experience and knowledge of
important standards, documentation and provisions, concerning safety and working conditions, have been authorized to carry out necessary work and are able to recognize potential hazards
and avoid them. This technical documentation must be delivered together with the device. The documentation contains information concerning all possible configurations of air curtains.
Examples of air curtain assembly and installation, as well as activation, use, repair and maintenance. Provided that the device is operated according to the intended use, this documentation
contains a sufficient number of instructions, required by the qualified personnel. The documentation should be placed near the device and be readily available to the service team. The
manufacturer reserves the right to introduce
changes
to the instruction, as well as changes to the device that affect its operation, without prior notice. VTS shall bear no responsibility for on-
going maintenance, inspections, programming of equipment and damage, caused by standstills of equipment related to the waiting for warranty services, all and any damage related to the
Client’s property, other than the device in question, as well as mal
functions that result from incorrect installation or improper use of the device.
WING air curtains are intended for indoor installation only.
DO NOT COVER
WARNING
: To avoid overheating - do not cover the device!
1.2. TRANSPORT
Prior to the installing and taking the device out of the cardboard box, it is required to check whether the cardboard box has not been damaged in any way and/or the adhesive tape (installed
at the company) has not been broken off or cut. It is recommended to check whether the
device’s
casing has not been damaged in transport. Should any of the above situation occur, please
contact us through telephone or e-mail: Tel. +1 470-809-6811, email:
fax: +1 470-809-6815.
The device should be transported by two people. Use appropriate tools, when transporting the device, so as to avoid the damaging of goods and potential hazard to health.
1.3. INITIAL STEPS TAKEN BEFORE THE INSTALLATION
Record the serial number of the device on the warranty card, prior to the commencement of the installation process. It is required to properly fill-in the warranty card, once the installation is
complete. Prior to the commencing of any installation or maintenance work, it is required to disconnect power supply and protect it against unintentional activation.
Installation and start-up should be performed by qualified personnel, according to the guidelines provided in this manual. The order of
installation steps are as follows:
•
Mount the device in its intended operation place
•
Perform the hydraulic connection, check connections for tightness and vent the system
•
Perform the electrical connection
•
Make sure the device is correctly connected (according to the diagram)
•
In the case of an electrical curtain, vacuum the heaters to avoid the unpleasant smell of burning dust
•
Turn the power on and start the device.
2. STRUCTURE, INTENDED USE, PRINCIPLE OF OPERATION
2.1. INTENDED USE
For the convenience of users as well as different types of installations in commercial and industrial facilities we have designed an air curtain in three different options and three sizes:
●
a WING W100 240/1/60 curtain 42in wide with a water heater (13.6-58MBH, 1089 CFM)
●
a WING E100 (models: WING E100 240/1/60, WING E100 240/3/60, WING E100 480/3/60) curtain 42in wide with electric heaters (6.8/13.6/20.5 MBH, 1089 CFM)
●
a WING C100 240/1/60 curtain 42in wide (1107 CFM)
●
a WING W150 240/1/60 curtain 62in wide with a water heater (34.1- 109 MBH, 1825 CFM)
●
a WING E150 (models: WING E10 240/3/60, WING E150 480/3/60) curtain 62in wide with electric heaters (13.6/27.3/40.9 MBH, 1854 CFM)
●
a WING C150 240/1/60 curtain 62in wide (1884 CFM)
●
a WING W200 240/1/60 curtain 82in wide with a water heater (58- 160 CFM, 2590 CFM)
●
a WING E200 (models: WING E200 240/3/60, WING E200 480/3/60) curtain 82in wide with electric heaters (20.5/30.7/51 MBH, 2649 CFM)
●
a WING C200 240/1/60 curtain 82in wide (2708 CFM)
The above sizes of curtains are available with three options of voltage supply: 1x240VAC, 3x240VAC, 3x480VAC
! Voltage supply 1x240VAC is available only for the curtains WING E100 240/1/60, all WING W and all WING C
! Caution
The following models of WING air curtains must be supplied using High-Leg Delta supplying
circuit:
•
WING E100 480/3/60 Air Curtain
•
WING E150 480/3/60 Air Curtain
•
WING E200 480/3/60 Air Curtain
For these models, the
L1-N
voltage will must be
240 VAC
.
The use of the WING air curtain enables the leaving of the room door open, regardless of weather conditions, thus providing a protective barrier. The curtain also enables a simultaneous keeping of
the required heating comfort inside the room/facility. The modern design of the WING air curtain is a result of its wide range of application. The places in which it is possible to install the device include:
malls, office buildings, supermarkets, cinema complexes, as well as shops, store-rooms, manufacturing facilities or warehouse rooms. Please notice that the use of an air curtain not only provides a
protective barrier, but also it is an additional heat source in the room.
APPLICATION:
warehouse rooms, warehouses, sports facilities,
supermarkets, religious buildings, hotels, clinics, pharmacies,
hospitals, office buildings, manufacturing facilities.
PRIMARY ADVANTAGES:
protection of climatic conditions in the room, reduction of heating/cooling costs, universal size, ability to work both in
vertical and horizontal position; simple, quick and intuitive assembly.
2.2. PRINCIPLE OF OPERATION
WING W100-200
- heating medium, for example hot heating water, returns
heat through a heat exchanger with a wide heat-exchange surface, thus
providing high heating output (13.6-160 MBH). A transverse fan (518-2590
CFM) sucks in the air in the room, and pumps it through the heat exchanger,
back into the room. The jet of warm air is directed downstream at high
velocity, thus providing an air barrier.
WING E100-200
- electric heaters (6.8-51.2 MBH) heat up, as a result of the
flowing of electric current, and return the heat to the air; the air is blown off
through the fan, which sucks in the air in the room. A jet of warm air is directed
downstream at high velocity, thus providing an air barrier.
EN
Summary of Contents for WING C100-200
Page 15: ...15 9 ELECTRICAL DIAGRAMS 9 1 Electrical diagram of WING W100 200 EC 1 240V ...
Page 17: ...17 9 3 Electrical diagram of WING E100 EC 1 240V ...
Page 18: ...WING W100 200 WING E100 200 WING C100 200 18 9 4 Electrical diagram of WING E100 EC 3 240V ...
Page 19: ...19 9 5 Electrical diagram of WING E100 EC 3 480V ...
Page 21: ...21 9 7 Electrical diagram of WING E150 200 EC 3 480V ...