background image

G0

G

A+

B- GND

Humidi Supply

G0

G

A+

B- GND

Humidi Room

G0 D01 G0

G

A02

Pump

G0

G0 A03 G0 A04

Dampers

Reserve Reserve

G0 D02 G0 D03 G0

Dampers

D04 G0 D05

Heat 2

Cool 1

Cool 2

24V, RS-485 - Modbus RTU

24V, RS-485 - Modbus RTU

Stop / Start

24V, 0-10V

0-10V

0-10V

Stop / Start

Stop / Start

Stop / Start

Stop / Start

G0

G

A+

B- GND

CO2

G0

G

A+

B- GND

HMI Basic

G0 DI1

Fire al.

G0

B1

G0

B2

G0

T. supply

B3

G0

B5

T. heater

T. room T. outside

24V, RS-485 - Modbus RTU

24V, RS-485 - Modbus RTU

NO / NC

NTC10k

NTC10k

NTC10k

NTC10k

G0

G

A+

B- GND

VOC

G0

G

A+

B- GND

Reserve

G0

G

Y1

G0

G

Y2

G0

G

Y3

G0

Heating

G0 DI4 G0 DI5 G0

Mode 1

DI6

Mode 2

Remote

24V, RS-485 - Modbus RTU

24V, RS-485 - Modbus RTU

24V, 0-10V

NO / NC

NO / NC

NO / NC

G0 DI2

Heater al.

NO / NC

G0 DI3

Cool al.

NO / NC

C6 D06

Global al.

Stop / Start

Recovery

24V, 0-10V

Cooling

24V, 0-10V

003

All rights reserved. 

Wszelkie prawa zastrzeżone.

Copyright © VTS sp. z o.o. 

Wszelkie prawa zastrzeżone.

Все права зарезервированы.

Ver. 2020.03.06

STEP 8

STEP 7

Connection of the fire alarm system, if exists

Connection of the functional elements of the AHU

G0

DI1

Fire al.

NO / NC

G0

DI2

Heater al.

NO / NC

G0

DI3

Cool al.

NO / NC

G0

DI1

G0

DI2

G0

DI3

Fire

Fire

alarm

NO / NC

G0

DI1

Fire al.

NO / NC

G0

DI2

Heater al.

NO / NC

G0

DI3

Cool al.

NO / NC

G0

DI1

G0

DI2

G0

DI3

Fire

G0

G

A+

B- GND

Humidi Supply

G0

G

A+

B- GND

Humidi Room

G0 D01 G0

G

A02

Pump

G0

G0 A03 G0 A04

Dampers

Reserve Reserve

G0 D02 G0 D03 G0

Dampers

D04 G0 D05

Heat 2

Cool 1

Cool 2

24V, RS-485 - Modbus RTU

24V, RS-485 - Modbus RTU

Stop / Start

24V, 0-10V

0-10V

0-10V

Stop / Start

Stop / Start

Stop / Start

Stop / Start

G0

G

A+

B- GND

CO2

G0

G

A+

B- GND

HMI Basic

G0 DI1

Fire al.

G0

B1

G0

B2

G0

T. supply

B3

G0

B5

T. heater

T. room T. outside

24V, RS-485 - Modbus RTU

24V, RS-485 - Modbus RTU

NO / NC

NTC10k

NTC10k

NTC10k

NTC10k

G0

G

A+

B- GND

VOC

G0

G

A+

B- GND

Reserve

G0

G

Y1

G0

G

Y2

G0

G

Y3

G0

Heating

G0 DI4 G0 DI5 G0

Mode 1

DI6

Mode 2

Remote

24V, RS-485 - Modbus RTU

24V, RS-485 - Modbus RTU

24V, 0-10V

NO / NC

NO / NC

NO / NC

G0 DI2

Heater al.

NO / NC

G0 DI3

Cool al.

NO / NC

C6 D06

Global al.

Stop / Start

Recovery

24V, 0-10V

Cooling

24V, 0-10V

G0 D01 G0

G

A02

Pump

G0

G0 A03 G0 A04

Dampers

Reserve Reserve

G0 D02 G0 D03 G0

Dampers

D04 G0 D05

Heat 2

Cool 1

Cool 2

Stop / Start

24V, 0-10V

0-10V

0-10V

Stop / Start

Stop / Start

Stop / Start

Stop / Start

1

2

3

G

0

G

D

0

2

C

a

b

le

3

x

0

,5

m

m

1

2

3

Terminal 1

Damper act.

Close / Open

2

2

4

V

D

C

+

O

n

/O

ff

1

3

2

1

3

2

1

2

3

G

0

G

D

0

2

C

a

b

le

3

x

0

,5

m

m

1

2

3

Terminal 1

Damper act.

Close / Open

2

2

4

V

D

C

+

O

n

/O

ff

Air damper actuator:

G0

DI1

Fire al.

NO / NC

G0

DI2

Heater al.

NO / NC

G0

DI3

Cool al.

NO / NC

G0

DI1

G0

DI2

G0

DI3

1/C

2/L

4/H

G0

DI2

Cable 2x0,5mm

1

2

Terminal 1

Thermostat

Water heater

2

G0

G

A+

B- GND

Humidi Supply

G0

G

A+

B- GND

Humidi Room

G0 D01 G0

G

A02

Pump

G0

G0 A03 G0 A04

Dampers

Reserve Reserve

G0 D02 G0 D03 G0

Dampers

D04 G0 D05

Heat 2

Cool 1

Cool 2

24V, RS-485 - Modbus RTU

24V, RS-485 - Modbus RTU

Stop / Start

24V, 0-10V

0-10V

0-10V

Stop / Start

Stop / Start

Stop / Start

Stop / Start

G0

G

A+

B- GND

CO2

G0

G

A+

B- GND

HMI Basic

G0 DI1

Fire al.

G0

B1

G0

B2

G0

T. supply

B3

G0

B5

T. heater

T. room T. outside

24V, RS-485 - Modbus RTU

24V, RS-485 - Modbus RTU

NO / NC

NTC10k

NTC10k

NTC10k

NTC10k

G0

G

A+

B- GND

VOC

G0

G

A+

B- GND

Reserve

G0

G

Y1

G0

G

Y2

G0

G

Y3

G0

Heating

G0 DI4 G0 DI5 G0

Mode 1

DI6

Mode 2

Remote

24V, RS-485 - Modbus RTU

24V, RS-485 - Modbus RTU

24V, 0-10V

NO / NC

NO / NC

NO / NC

G0 DI2

Heater al.

NO / NC

G0 DI3

Cool al.

NO / NC

C6 D06

Global al.

Stop / Start

Recovery

24V, 0-10V

Cooling

24V, 0-10V

1

2

1

2

1/C

2/L

4/H

G0

DI2

Cable 2x0,5mm

1

2

Terminal 1

Thermostat

Water heater

2

Anti-frost thermostat for water heater

1

2

Summary of Contents for Ventus VVS005s-030s

Page 1: ...e STEP 1 AHU and CBX types Unpacking automation elements STEP 2 VVS021c 150c VVS005s 030s Note In case aof outdoor installation of the Air Handling Units VVSc range only All cables should be secured b...

Page 2: ...0V Stop Start Stop Start Stop Start Stop Start G0 G A B GND CO2 G0 G A B GND HMI Basic G0 DI1 Fire al G0 B1 G0 B2 G0 T supply B3 G0 B5 T heater T room T outside 24V RS 485 Modbus RTU 24V RS 485 Modbus...

Page 3: ...odbus RTU 24V RS 485 Modbus RTU NO NC NTC10k NTC10k NTC10k NTC10k G0 G A B GND VOC G0 G A B GND Reserve G0 G Y1 G0 G Y2 G0 G Y3 G0 Heating G0 DI4 G0 DI5 G0 Mode 1 DI6 Mode 2 Remote 24V RS 485 Modbus R...

Page 4: ...G0 G Y1 G0 G Y2 G0 G Y3 G0 1 2 5 G0 G Y1 Cable 3x0 5mm 1 2 3 Terminal 1 Heater act 2 24V DC 0 10V DC 1 2 5 G0 G Y1 Cable 3x0 5mm 1 2 3 Terminal 1 Heater act 2 24V DC 0 10V DC 1 2 3 1 2 3 3 3a Main hea...

Page 5: ...lobal al Stop Start Recovery 24V 0 10V Cooling 24V 0 10V G0 B1 G0 B2 G0 T supply B3 G0 B5 T heater T room T outside NTC10k NTC10k NTC10k NTC10k G0 B1 G0 B2 G0 B3 G0 B5 1 2 G0 B5 Cable 2x0 5mm 1 2 2 Te...

Page 6: ...prawa zastrze one Electric heater G0 G Y1 G0 G Y2 G0 G Y3 G0 Heating 24V 0 10V Recovery 24V 0 10V Cooling 24V 0 10V G0 G Y1 G0 G Y2 G0 G Y3 G0 1 3 2 3 2 Make holes for power supply and control cables...

Page 7: ...DC Control cable PreHeater ReHeater 7c Ver 2021 09 16 G 3 4 3 4 HE PowerBox Terminal X1 AHU Terminal 1 D01 5 X 5 6 6 G0 A1 7 DI2 A2 8 Y1 2 2 G0 1 1 D06 G0 DI2 A03 G0 G0 DI2 A04 G0 Hum DXH type G D06 G...

Page 8: ...0 B2 G0 T supply B3 G0 B5 T heater T room T outside 24V RS 485 Modbus RTU 24V RS 485 Modbus RTU NO NC NTC10k NTC10k NTC10k NTC10k G0 G A B GND VOC G0 G A B GND Reserve G0 G Y1 G0 G Y2 G0 G Y3 G0 Heati...

Page 9: ...GND Humidi Room G0 D01 G0 G A02 Pump G0 G0 A03 G0 A04 Dampers Reserve Reserve G0 D02 G0 D03 G0 Dampers D04 G0 D05 Heat 2 Cool 1 Cool 2 24V RS 485 Modbus RTU 24V RS 485 Modbus RTU Stop Start 24V 0 10V...

Page 10: ...1 2 3 4 5S Terminal 1 HMI Basic 2 24V DC Modbus RS 485 G0 G A B GND CO2 G0 G A B GND HMI Basic 24V RS 485 Modbus RTU 24V RS 485 Modbus RTU G0 G A B GND G0 G A B GND GND 24V Rx G0 G A Cable 4x0 5mm Sh...

Page 11: ...485 Modbus RTU 24V RS 485 Modbus RTU 24V 0 10V NO NC NO NC NO NC G0 DI2 Heater al NO NC G0 DI3 Cool al NO NC C6 D06 Global al Stop Start Recovery 24V 0 10V Cooling 24V 0 10V Humidity limiting sensor 1...

Page 12: ...elkie prawa zastrze one Copyright VTS sp z o o Wszelkie prawa zastrze one Ver 2020 09 04 Power connection 13 Main swich Q0 PE 3 400V N L1 L2 L3 Cable out of delivery 1 230V L N Cable out of delivery P...

Reviews: