Place the terminal back to the thermostat, make
sure it has the same orientation like in the picture
described at the back. Snap the thermostat to its
back plate.

Fig. 7. Connecting  wire.

Loosen the terminal screw, strip the wire and
connect the wire as shown in fig 7. Firmly tighten
terminal screw when finished.

Set-up switch (E/F)

WARNING

        

Fire Hazard.

Failure to set the set-up switch to the E position
when electric resistance heat is used may result
in the overheating of the electric heater elements
due to improper fan operation.

The set-up switch is an internal switch (E,F)
located near the wiring terminals. It is used to
select proper fan operation for the heating
system being used.

q

 

The E position is for electric heat  and single
stage heat pump applications.

q

 

The F position is for fuel applications.

Fig. 8. Setup switch.

Fig. 6b. Wiring Diagram for

single stage heat pump.

HEAT PUMP WITH

HEAT ACTIVE

REVERSING VALVE

HEAT PUMP WITH

COOL ACTIVE

REVERSING VALVE

*Note: Set-up
switch must be
in E position.

*Note: Set-up
switch must be
in E position.

Fig. 9. Installing thermostat.

Summary of Contents for TE86S

Page 1: ...hermostat Model Mounting System Selection Fan Selection Powering Method Backlight TE86S VERTICAL COOL OFF HEAT ON AUTO Power Stealing No Backlight TE86SB VERTICAL COOL OFF HEAT ON AUTO Power Stealing...

Page 2: ...d 1 5 Amp continuous 0 02 to 1 5 A continuous 0 02 to 1 5 A continuous 0 02 to 0 5 A continuous TEMPERATURE RATINGS Temperature setting range Ambient temperature range Shipping temperature range 40 to...

Page 3: ...as indicated will result in poor temperature control NOTE Level thermostat mounting is for appearance only and is not required for proper thermostat operation Mounting Thermostat Take out the back pl...

Page 4: ...s used may result in the overheating of the electric heater elements due to improper fan operation The set up switch is an internal switch E F located near the wiring terminals It is used to select pr...

Page 5: ...following steps to change each of the settings Each time you press D key you will advance to the next operating parameter To go back you must re enter the installer set up as described above INSTALLER...

Page 6: ...hould consult with the heating equipment manufacturer for proper use Setting cooling algorithm OP 04 The cooling algorithm can be selected as normal or aggressive For aggressive the system will cool d...

Page 7: ...and cooling are off Fan Setting Fan switch settings are On Fan symbol is indicated on the display The fan runs continuously Used to improve air circulation and air quality Auto Fan and Auto symbols a...

Page 8: ...p switch is in the F position the fan is controlled directly by the heating equipment and may start a few minutes after the heating equipment turns on When setup switch is in the E position the fan st...

Reviews: