background image

               Vtronix

1

TE86S,TE86SB

Digital Thermostat

INSTALLATION MANUAL

APPLICATION

The TE86S Thermostat provides universal replacement of single-stage, 24Vac (20 mA to 1.5A) thermostats
used in electric, gas, and oil heating and cooling systems. This thermostat is mercury free and requires no
batteries. The thermostat also can be used to control single stage heat pumps.

The  TE86S  uses  advanced  proportional  plus  integral  (P+I)  control  for  optimum  temperature  control  and
comfort.

Table 1. Description of  Thermostat.

Model

Mounting

System Selection

Fan Selection

Powering

Method

Backlight

TE86S

VERTICAL

COOL-OFF-HEAT

ON-AUTO

Power Stealing

No Backlight

TE86SB VERTICAL

COOL-OFF-HEAT

ON-AUTO

Power Stealing

Backlight

Fig. 1.Thermostat

FEATURES

-

 

Stylish design, replaces Honeywell T834C, White Rodgers 1E56 or Lux PSD150.

-

 

LCD display with back lighting lit all the time (TE86SB).

-

 

Power stealing for universal replacement. No common wire required. No batteries.

-

 

Heat cycle rate can be selected (1,3,4,5,6,9,12) by software to suit many heating applications.

-

 

Heating / cooling damper output to control either dampers or heat pump reversing valve.

-

 

User options and set point are retained in the event of lost power.

Summary of Contents for TE86S

Page 1: ...hermostat Model Mounting System Selection Fan Selection Powering Method Backlight TE86S VERTICAL COOL OFF HEAT ON AUTO Power Stealing No Backlight TE86SB VERTICAL COOL OFF HEAT ON AUTO Power Stealing...

Page 2: ...d 1 5 Amp continuous 0 02 to 1 5 A continuous 0 02 to 1 5 A continuous 0 02 to 0 5 A continuous TEMPERATURE RATINGS Temperature setting range Ambient temperature range Shipping temperature range 40 to...

Page 3: ...as indicated will result in poor temperature control NOTE Level thermostat mounting is for appearance only and is not required for proper thermostat operation Mounting Thermostat Take out the back pl...

Page 4: ...s used may result in the overheating of the electric heater elements due to improper fan operation The set up switch is an internal switch E F located near the wiring terminals It is used to select pr...

Page 5: ...following steps to change each of the settings Each time you press D key you will advance to the next operating parameter To go back you must re enter the installer set up as described above INSTALLER...

Page 6: ...hould consult with the heating equipment manufacturer for proper use Setting cooling algorithm OP 04 The cooling algorithm can be selected as normal or aggressive For aggressive the system will cool d...

Page 7: ...and cooling are off Fan Setting Fan switch settings are On Fan symbol is indicated on the display The fan runs continuously Used to improve air circulation and air quality Auto Fan and Auto symbols a...

Page 8: ...p switch is in the F position the fan is controlled directly by the heating equipment and may start a few minutes after the heating equipment turns on When setup switch is in the E position the fan st...