![VTech ErisTerminal VSP726 Administrator And Provisioning Manual Download Page 210](http://html1.mh-extra.com/html/vtech/eristerminal-vsp726/eristerminal-vsp726_administrator-and-provisioning-manual_1054365210.webp)
Configuration File Parameter Guide
210
VSP726 Administrator and Provisioning Manual
Setting:
tone.call_waiting_tone.element.x
Description:
Defines the call waiting tone element x (x = 2–5).
Values:
Tone element string
Default:
Blank
Setting:
tone.call_waiting_tone.num_of_repeat_all
Description:
Sets the number of repeats of all elements in sequence; that is, repeating
back to the first element.
Values:
0–65535
Default:
0
Setting:
tone.hold_reminder_tone.num_of_elements
Description:
Sets the number of tone elements for the hold reminder tone.
Values:
1–5
Default:
1
Setting:
tone.hold_reminder_tone.element.1
Description:
Defines the hold reminder tone element 1.
Values:
Tone element string
Default:
1 770 -22 0 0 0 0 0 0 300 0 1
Setting:
tone.hold_reminder_tone.element.x
Description:
Defines the hold reminder tone element x (x = 2–5).
Values:
Tone element string
Default:
Blank
Setting:
tone.hold_reminder_tone.num_of_repeat_all
Description:
Sets the number of repeats of all elements in sequence; that is, repeating
back to the first element.
Values:
0–65535
Default:
0
Setting:
tone.inside_dial_tone.num_of_elements
Description:
Sets the number of tone elements for the secondary dial tone (see
for description and behavior).
Values:
1–5
Default:
1