background image

Features/Operation

continued

7

V-Top Drain Trough:

V-top surgery tables feature a removable
drain trough for easy cleaning. To remove
the drain trough, first lower the V-panels
to the flat position.  The drain trough will
slide out of the “uphill” end of the table. 

The drain reservoir will
now slide out of the table

Unhook
drainage
reservoir
retainer

Rail Extensions:

All tables may be ordered with an 
optional pair of 14" long rail extensions
to accommodate larger animals. Each pair 
of extensions includes two quick-release
restraint cleats. Refer to page 9,
“Accessories”, for more information.

Rail 

Extensions

Restraint

Cleats

Flat-Top Drainage:

The flat-top surgery table drains into a
stainless steel bucket (not included).
Refer to page 9, “Accessories”, for 
ordering information.

V-Top Drainage Reservoir:

V-top surgery tables feature a slide-out
drainage reservoir that catches waste 
fluids as they drain from the drain trough.
To remove the drainage reservoir for
cleaning, unhook the metal retainer hook
and slide the reservoir out.

Troubleshooting

In the event that a problem occurs, a VSSI
factory technician is ready to assist you.
Please call VSSI for assistance before 
attempting any repairs.

VSSI Technical Support: 

1-800-299-9525

Summary of Contents for Flat-Top

Page 1: ...Instruction Manual Pre Installation 2 V Top Parts Identification 2 Flat Top Parts Identification 3 Installation 3 4 Features Operation 5 7 Troubleshooting 7 Care Cleaning 8 Specifications 8 Accessories 9 Product Warranty 10 Table of Contents ...

Page 2: ...t to move the surgery table by yourself it is very heavy Improper handling may result in injury to yourself or damage to the product Refer to drawings on this and the following page to identify features of The VSSI Hydraulic Surgery Table V Top Parts Identification Top Tilt Adjustment Control Lever Under end of top Hydraulic Column Foot Pedal Low Profile Base with Stainless Steel Cover Quick Relea...

Page 3: ...ing and carrying the table To Lift The V top Surgery Table When moving a V top surgery table NEVER lift the table by its V panels If your table is equipped with the adjustable column lower the table top to its lowest position This will be the position the table has arrived in Refer to Features Operation page 5 for adjusting instructions continued Top Tilt Adjustment Control Lever Under end of top ...

Page 4: ...o be removed easily for cleaning Surgery tables equipped with the heated top option need to be within reach of a standard power outlet 3 After the table is in position snap the non skid rubber pads over the metal adjusting feet If you are using the optional casters unscrew the metal adjusting feet and screw the casters into the same threaded holes The caster set includes four locking swivel caster...

Page 5: ...ing greater resistance if you depress the pedal until it stops you are releasing the hydraulic cylinder in effect lowering the table To lower the height of the table depress the pedal completely and hold until the table sinks to the desired position Depress Foot Pedal to bottom position to lower the table RAISING THE TABLE LOWERING THE TABLE Pedal returns to up position automatically Step on Foot ...

Page 6: ...he cleats to hold the patient securely in place To release simply pull the tie down strap in a downward outward motion Heated Top Option The optional heated top provides thermal support to help prevent hypothermia during surgery The heated top should be between 15 and 25 above ambient room temperature however all patients should be monitored continuously to prevent any possible over heating Heat c...

Page 7: ...k release restraint cleats Refer to page 9 Accessories for more information Rail Extensions Restraint Cleats Flat Top Drainage The flat top surgery table drains into a stainless steel bucket not included Refer to page 9 Accessories for ordering information V Top Drainage Reservoir V top surgery tables feature a slide out drainage reservoir that catches waste fluids as they drain from the drain tro...

Page 8: ...lorine bleach for cleaning Chlorides bromides iodides and thiocyanates will cause pitting corrosion and discoloration of any stainless steel If using bleach clean thoroughly with water to completely remove bleach residue Avoid excessive moisture The VSSI Hydraulic Surgery Table contains electronic components that may be damaged by excessive exposure to moisture When cleaning or mopping the floor d...

Page 9: ...olumes of fluids Stainless steel construction is extremely durable and easy to clean No 200 3041 02 Large Drip Bucket 13 qt For flat top surgery tables the 2 quart drip bucket is available for smaller volumes of fluids Durable stainless steel construction is easy to clean No 200 3041 03 Small Drip Bucket 2 qt 10 stainless steel table top extensions for V top surgery tables are available Extensions...

Page 10: ...with this Return Authorization Number All items must have a Return Authorization Number Return the items postage freight prepaid If necessary the VSSI sales representative will assist you with freight arrangements Note Custom orders and or custom colors may not be returned Product Warranty This product is warranted for 1 year from the date of delivery to the original purchaser only Warranty is onl...

Reviews: