VSpeak Electronic switch 2A (opto) Manual Download Page 3

 

Electronic switch 2A (opto) 

www.VSpeak-modell.de

 Page 

3/4 

will memorize these positions and switch "ON", as long the signal is within this range. 
Remove the magnet when you are done. 

4

 

LED-Display 

4.1

 

internal green LED 

OFF: 

Switch is OFF 

ON: 

Switch is ON 

Blinking:  Magnet near Sensor, switch status is kept on previous state 
 -or- 
 

Fault, no servo signal for more than 2.5 seconds, switch is "OFF" 

Flickering: Programming mode, switch is "ON" 

4.2

 

external blue LED 

OFF: 

Load is switched "OFF", no connection to the load battery 

ON: 

Load is switched "ON", power from load battery

 

5

 

Technical data 

Servo input 

3,0 … max 15V 

Switching voltage 

3,0 … max 20V 

(3…13 Cells NiCd/NiMh, 1 to 4 Cells LiPo)

 

Switch current 

max 2 A 

Power consumption

 

(control part, powered by the RX) 

ON:  about 9 mA 

OFF: about. 2 mA 

Power consumption

 

(switching part, powered by the 
external battery) 

ON:  about 8 mA/ 2mA    with / without external blue LED

OFF: ~

0 mA

   

(max. 0,001 mA)

 

Size 

30 x 9 x 8 mm 

(PCB)

 

Weight 

6 g   (incl. Cable) 

Connectors 

RX cable (0,14 mm²) 

switching part: 3-wire cable (0,25 mm²) 

2-pin socket for the external blue LED 

The "ON" range can be programmed completely free. 