VS V91 MAX Operating & Maintenance Manual Download Page 4

 

VS Security Products LTD

 

ZZ009174, ZZ009177

 

Page 4 of 15

 

 

 

 

SECTION 1:  S P E C I F I C A T I O N

 

 

 

   

 

 

 

MEDIA HANDLING

   

 

 

Standard Hard drives 

-

 PC, Laptop and Server 

3.5”, 2.5” &1.8”, 

  

   

 

 

 

 

 

Longitudinal & perpendicular recording up to 2TB, All drive interfaces 

-

 

   

 

 

 

 

 

IDE, SATA and Fibre Channel.

 

 

 

   

 

 

 

 

 

All backup tapes including: DLT, S

-

DLT, LTO1, 2, 3, 4, 5, 6  &7. 

 

   

 

 

 

 

 

3480/3490/3490e,3590,9840,T9940 & T10000 tape; Ultrium & Redwood 

   

 

 

 

 

 

SD

-

3 tape & cartridges; Mammoth 1 & 2,8mm, AIT1 & 2, M2 tape; DDS 

   

 

 

 

 

 

1, 2, 3, 4 & 5, DD

-

2.

 

 

 

   

 

 

 

 

 

½

” 

Computer Tape, Diskettes (Single & Boxed), DC 600 & 2000, TK50, 

   

 

 

 

 

 

70 & 85, 4mm & 8mm, Exabyte, Travan, DAT, ZIP Disk, Ultrium, 

 

   

 

 

 

 

 

HDCam, HD CAM SR, VHS, SVHS, U

-

Matic, Betacam, Digital Betacam 

   

 

 

 

 

 

SP, MII, D1, 2, 3 & 5, DVC Pro, Hi

-

8, Mini DV. 

 

 

 

   

 

 

 

 

 

1” 

Tape on Reels

 

 

 

ERASURE DEPTH

   

 

 

-

75db on 1500 Oe tape

 

 

   

 

 

 

 

 

-

90db on 750 Oe tape

 

 

 

 

DUTY CYCLE

   

 

 

 

20% (Dependant on ambient temperature)

 

 

RUN TIME

 

 

 

 

 

2 minutes

 

 

ERASURE TIME

 

 

 

 

20 seconds typical

 

 

 

OPERATING VOLTAGE

 

 

 

ZZ009177: 220

-

240v (50Hz)

 

 

   

 

 

 

 

 

ZZ009174: 208

-

220v (60Hz) 

 

 

 

 

CURRENT

 

 

 

 

 

10 amps typical 220

-

240v 50Hz

 

 

   

 

 

 

 

 

12 amps typical 208

-

220v 60Hz

 

 

 

CIRCUIT BREAKER

  

 

 

ZZ009177: 12A (50Hz)

 

 

   

 

 

 

 

 

ZZ009174: 15A (60Hz)

 

 

 

SECURITY KEY SWITCH

   

 

Standard

 

 

 

 

 

MOUNTING

   

 

 

 

Free standing table top

 

 

 

DIMENSIONS

   

 

 

 

19’’ 

16.5’’ 

6’’ 

(48cm x 42cm x 15cm)

 

 

DIMENSIONS (PACKED)

   

 

25.5’’ 

20.8’’ 

10.6’’ 

(65cm x 53cm x 27cm)

 

 

 

 

   

 

 

 

 

 

 

 

 

 

WEIGHT

 

 

 

 

 

57 lbs (26kg)

 

 

WEIGHT (PACKED)

   

 

 

62 lbs (28kg)

 

 

 
 

 

ENVIRONMENTAL PROTECTION

 

This product must not be disposed of with household waste. You are responsible for 

ensuring and financing all costs of collection, treatment, recovery and 

environmentally sound disposal of the goods in accordance with the WEEE directive.

 

 

Registered Producer Number: WEE/JB2622WS

 

VS Security Products reserves the right to amend or modify the specifications and design criteria applying to 
these products

 

Summary of Contents for V91 MAX

Page 1: ...ZZ009174 ZZ009177 Rev 12 ...

Page 2: ...metres 6 Feet from the degausser IMPORTANT the power on off switch used on this equipment is not an isolating switch it is recommended that this equipment should be operated from a separate switched isolator which should be located close to the unit and within reach of the operator COPYRIGHT This document is the property of VS Security Products Ltd and it may not be reproduced copied or exhibited ...

Page 3: ... S SECTION PAGE 1 Specification 4 2 Introduction to the V91 MAX Degausser 5 3 Installation 5 4 Operation 6 5 Indicators Features 8 6 Maintenance Service 9 7 Tables 10 8 Parts List 11 This document refers to V91 MAX part no s ZZ009174 208 220v 60Hz ZZ009177 220 240v 50Hz ...

Page 4: ...DUTY CYCLE 20 Dependant on ambient temperature RUN TIME 2 minutes ERASURE TIME 20 seconds typical OPERATING VOLTAGE ZZ009177 220 240v 50Hz ZZ009174 208 220v 60Hz CURRENT 10 amps typical 220 240v 50Hz 12 amps typical 208 220v 60Hz CIRCUIT BREAKER ZZ009177 12A 50Hz ZZ009174 15A 60Hz SECURITY KEY SWITCH Standard MOUNTING Free standing table top DIMENSIONS 19 x 16 5 x 6 48cm x 42cm x 15cm DIMENSIONS P...

Page 5: ... MAX eraser The V91 MAX is capable of removing data from PC hard drives in less than 20 seconds Although in most cases this will render the hard drive inoperative the cost of a replacement hard drive cannot be compared to the cost to a company if sensitive information can be read by a third party DLT Anyone replacing their existing DLT drive with the new DLT1 drive should be aware that their exist...

Page 6: ... switch option fitted the power switch will illuminate as normal when switched on but will also require the key switch to be turned clockwise for correct operation NOTE Where a security key switch is fitted the degaussing coil must only be energised and de energised by using the power switch i e use the RED BUTTON to switch power ON OFF NOT the key switch 4 2 Erasure of Hard Drives Because of the ...

Page 7: ...be turned through 90 degrees and a second pass made the media must be turned over and the process repeated making a total of four passes to ensure complete erasure 4 4 Erasure of Reels and Pancakes The media in reel or pancake form to be erased should be brought slowly towards the top surface The media should be placed on the surface and rotated slowly and evenly taking approximately five seconds ...

Page 8: ...d by the degaussing magnetic field and is considered more reliable being a red flashing LED 5 3 Overheat Protection The high energy field developed by the V91 MAX necessitates the generation of a considerable amount of heat The de gausser coil is monitored for excessively high temperatures and should this condition occur its operation will be inhibited until the coil has cooled sufficiently 5 4 Co...

Page 9: ...protected and does not require servicing However in the event of failure the fan may easily be replaced from the rear of the degausser 6 4 Internal Components Most of the internal components are replaceable i e the solid state relay toroidal transformer and the thermal switches mounted on the degausser coil However the tuning capacitors and the degaussing coil are not spared items and if found to ...

Page 10: ...l L1 and or tuning capacitors C1 C4 User source Inside centre and left hand side Power lamp Fails to illuminate Loss of mains supply Tripped circuit breaker Faulty switch Faulty neon User source Rear panel Front panel Front panel Degauss lamp Fails to illuminate flashes Extensive use of degausser caused overheating Allow unit to cool Not a fault Faulty Neon Faulty solid state relay R1 Faulty therm...

Page 11: ... Relay SH100150 1 Relay Cover SW3 SP100002 1 Temperature Sensor SW2 SW100016 2 Thermal Switch CB1 SW100017 1 15A Circuit Breaker SW1 SW100123 1 Red lens SW1 SW100125 1 Switch Body SW1 SW100126 1 Switch Contact Block IND1 SW100121 1 Yellow lens IND1 SW100124 1 Indicator IND1 SW100127 1 Dummy Socket TX1 TX100027 1 Auto Toroid Transformer MP003065 1 Fan Plate SW4 SW100070 1 Security Key Switch IND2 O...

Page 12: ...elay SH100150 1 Relay Cover SW3 SP100002 1 Temperature Sensor SW2 SW100016 2 Thermal Switch CB1 SW100066 1 12A Circuit Breaker SW1 SW100123 1 Red lens SW1 SW100125 1 Switch Body SW1 SW100126 1 Switch Contact Block IND1 SW100121 1 Yellow lens IND1 SW100124 1 Indicator IND1 SW100127 1 Dummy Socket TX1 MP002325 1 Filter XX001118 1 Fan Plate SW4 SW100070 1 Security Key Switch IND2 OI100017 1 Flashing ...

Page 13: ...VS Security Products LTD ZZ009174 ZZ009177 Page 13 of 15 8 3 Circuit Diagram ZZ009177 50Hz ...

Page 14: ...VS Security Products LTD ZZ009174 ZZ009177 Page 14 of 15 8 4 Circuit Diagram ZZ009174 60Hz ...

Page 15: ...VS SECURITY PRODUCTS LIMITED VS AND ASSOCIATES Unit 17 Pegasus Court 3160 Texas Hill Road North Lane Placerville Aldershot California GU12 4QP 95667 UK USA ...

Reviews: