VS LIGHTING SOLUTIONS Blu2Light Quick Manual Download Page 2

Service

Vossloh-Schwabe Deutschland GmbH

P.O. Box 28 69

D-58478 Lüdenscheid, Germany

Phone: +49 (0)23 51/10 10

[email protected]

For further information please visit our website: www.vossloh-schwabe.com

ENGLISH

EN

Safety  notes  

!

The Blu2Light products may only be installed and commissioned by authorised specialists. Read 

these instructions carefully before installing and commissioning the system. This is the only way to 

ensure safe and correct handling. Keep this manual in a safe place so that it may be available at a 

later date. Before any work is carried out on the equipment, it must be disconnected from the mains. 

When used in IT power networks, a 2-pole fuse must be provided, which disconnects the device 

from the mains on all poles. Carry out a condition test. The applicable safety and accident prevention 

regulations must be observed. Improper opening of the products is not permitted, there is a danger to 

life due to electrical voltage. Repairs may only be carried out by the manufacturer.  

Bluetooth

®

 wireless technology

The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth

SIG, Inc. and any use of such marks by Vossloh-Schwabe is under license. Other trademarks

and trade names are those of their respective owners.

We, Vossloh-Schwabe Deutschland GmbH, herewith confirm that these devices comply with the 

basic requirements of the directive 2014/53 / EU and other relevant directives. The entire text of the 

declaration of conformity can be obtained from the following address: Vossloh-Schwabe Deutschland 

GmbH, Hohe Steinert 8, D-58509 Lüdenscheid

                 Attention 230 VAC

Make sure that they are de-energized and that the corresponding fuse is switched off and 

secured. The mains voltage may only be switched on again after all switches/buttons and 

covers have been fitted.

Installation

• 

The 4-fold digital input module is intended for use in a standard flush-mounted box.

•  First connect the push-button / switch to the Connect PB4 module via the push-in terminals 

(T1, T2, T3, T4, COM).

•  Pay attention to the correct polarity according to the connection markings!

•  Assembly of the push-button cover.

•  Switch on the power supply.

Observe correct polarity

Pay attention to the correct polarity of L and N 

Installation instructions

•  Only buttons or switches suitable for mains voltage may be connected to inputs T1/T2 and COM.

•  The module must be placed inside the switch box and connected to the 230 VAC supply via a 

terminal.

•  Make sure that the polarity of L and N is correct.

Setup and operation

• 

The Blu2Light devices are configured with the LiNA Connect app and can be operated via the 

LiNA Touch app.

• 

For the exact procedure for the configuration of the devices please refer to the instructions in the 

LiNA Connect app or in the corresponding documentation.

•  A tablet is required for setup, both tablets and smartphones can be used for operation. Both are 

not included in the scope of delivery.

App operating mode and operating devices

LiNA Connect (configuration)

iOS

iPad

version 10 and higher

LiNA Touch (operation)

iOS

Android

Tablet

version 10 and higher

version 5.0 or higher

Smartphone

version 10 and higher

version 5.0 or higher

Technical Notes

Ref.-No. Connect PB4 186914

Communication: Blu2Light mesh network 

Power supply: 220...240 V at 50...60 Hz  

Power consumption: max. 0,5 W  

Frequency range: 2402-2480 MHz 

Output power: < 10 mW EIRP 

Ambient temperature ta: 5-40 °C 

Protection class: IP20 

Protection class II 

Housing diameter: 53 mm 

Housing height: 22.5 mm 

Housing: Polycarbonate, white 

Weight 40 g  

Push-in terminals: for flexible and rigid conductors with max. cross section 1.5 mm²

 

(L, N, COM, T1, T2, T3, T4)

Input T1, T2, T3, T4: max. 20 cm wire length per terminal

Schaltbild / Wiring diagram

Reviews: